Energate RM41F Quick Installation Manual Download Page 2

 

 

 

 

 

 

 

 

 

 

Pager Module Installation 

Page 2

 

AW000924-B

 

 

7.

 

From the Thermostat main menu, navigate to the 

Installer Setup

 menu. 

When the pager module is installed and working properly, the 

Pager

 option is displayed in the 

Installer Setup menu. Use this option to access information about the pager module’s connection to 

the network and other troubleshooting information. 

Pager Module Signal Status 

The thermostat cannot receive messages or DR events until it is provisioned using the CCDR website 

provided by the electric utility. 
After the pager module is provisioned, the link status indicator at the top right of the Temperature or 

Energy home screen displays the status of the Foundation’s wireless uplink signal(s). The following 

indicators can be displayed to the right of the signal strength bars: 

 

F:

 Thermostat is receiving communications from its server using the pager module. 

 

D:

 Thermostat is communicating with its server using both the pager module and a ZigBee 

gateway (dual wireless uplinks). 

 

Z:

 Thermostat is communicating with its server using a ZigBee gateway. 

Pager Link Information 

Use the Pager menu’s 

Link Info

 option to display information such as connection status, pager radio signal 

strength, and hardware/firmware version information. A two-digit confirmation code (CC) is displayed in 

the bottom-right corner of the Link Info screen, verifying successful provisioning. 
The first Link Info screen displays the current status of the pager module’s connection to the network: 

Message 

 

Description

 

CONNECTION 

ACTIVE 

Normal condition when working correctly. 

Foundation is connected to and successfully communicating with the CCDR 

server over the pager radio network. 

 

SEARCHING FOR 

NETWORK 

The pager module is working but is unable to detect the pager network.

 

NETWORK LOST 

The pager module is working and was previously connected to the pager 

network, but is no longer communicating with the network.

 

PAGER HARDWARE 

ERROR 

There is a problem with the pager module related to its hardware or 

configuration. Please contact technical support. 

WAITING FOR 

COMMISSION  

The pager module is working, has detected the pager network, and is waiting 

to be provisioned (commissioned). 

WAITING FOR 

BEACON 

The pager module is connected to the pager network but is waiting for a 

beacon signal from the pager network.  

The Foundation cannot be provisioned until it receives the beacon signal.

 

For information on troubleshooting a pager module installation, see the Troubleshooting section in 

Installation Guide for Energate Thermostats

Compliance Information 

Product: Flex Pager USNAP Radio Module 
Model: RM41F 
Responsible Party: Energate Inc., 2379 Holly Lane, Suite 

200, Ottawa, Ontario K1V 7P2, Canada. T.: 613-482-7928 
This equipment is RoHS compliant. 
This device complies with part 15 of the FCC Rules. 

Operation is subject to the following two conditions: (1) 

This device may not cause harmful interference, and (2) 

this device must accept any interference received, 

including interference that may cause undesired 

operation. 
Changes or modifications not expressly approved by the 

party responsible for compliance could void the user's 

authority to operate the equipment 
This device complies with Industry Canada licence-

exempt RSS standard(s). Operation is subject to the 

 

interference, and (2) this device must accept any 

following two conditions: (1) this device may not cause 

interference, including interference that may cause 

undesired operation of the device. 
Le présent appareil est conforme aux CNR d'Industrie 

Canada applicables aux appareils radio exempts de 

licence. L'exploitation est autorisée aux deux conditions 

suivantes : (1) l'appareil ne doit pas produire de 

brouillage, et (2) l'utilisateur de l'appareil doit accepter 

tout brouillage radioélectrique subi, même si le 

brouillage est susceptible d'en compromettre le 

fonctionnement. 
This Class B digital apparatus complies with Canadian 

ICES-003. 
Cet appareil numérique de la classe B est conforme à la 

norme NMB-003 du Canada. 
Cet appareil numérique de la classe B est conforme à la 

norme FCC 47 CFR Part 15.

 

 

Reviews: