background image

 

 

1.2. 

BATTERY IDENTIFICATION DATA 

 

 
BATTERY  IDENTIFICATION  DATA  ARE  INDICATED  ON  A  PLATE 
LOCATED  ON  ITS  CASE.  THE  PICTURE  SHOWS  THE 
COMPOSITION OF THE IDENTIFICATION PLATE.

 

 

 

 

1.3. 

WARRANTY 

 

The battery referred to this Manual, is guaranted accordino to the law, effective from the date of invoice. 
 
The Warranty is no more valid if : 
 

 

Terms for maintenance not respect ( recharge ). 

 

Terms for conservation e/o off duty not respected 

 

Damages  due  to  a  wrong  use  ,  to  be  more  precise  functioning  limits  overcoming  (

see  technical  data 

schedale 

)

 

 

Deformation or breakage of the box. 

 

Opening of the box. 

 

Replacement of the screws present on the poles with others of different lenght. 

 

Routine service or maintenance effected from 

NOT qualified personnel.

 

 

Use of battery charter / maintainers 

NON APRROVED BY ENERGA

 .

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Li - Ion  Battery Pack

 

Model: xx – xx

 

Product n°: 000000

 

Nominal value: 13,2V  xx Ah

 

Vmax charge: 14,5 V

 

Imax charge: xx A

 

Discharge peak current: xxA

 

 

Summary of Contents for 13-3A

Page 1: ...secuted according to the law The Company reserves the right to make changes and improvements on the machine at any time and without advance notice INSTRUCTION USE AND MAINTENANCE MANUAL Revision 1 date 01 10 2011 Distributor Walkers Garage Ltd Northallerton DL7 9HT 0044 0 1609 777221 LiFePO4 Lithium Starter battery Models 13 3A Ref LITH 120 ...

Page 2: ...ERAL SAFETY WARNINGS 4 1 2 BATTERY IDENTIFICATION DATA 5 1 3 WARRANTY 5 2 BATTERY FEATURES 6 2 1 NORMATIVE REFERENCES 6 2 2 TECHNICAL FEATURES AND DIMENSIONS 6 3 INSTALLATION 7 3 1 PRELIMINARY PROCEEDINGS 7 3 2 PLACE OF INSTALLATION 7 3 3 CONNECTION 7 3 4 BATTERY CHARGER 7 4 MAINTENANCE 7 4 1 MAINTENANCE E O PRESERVATION 7 ...

Page 3: ...omposed by A Identification Cover B Index of Chapters C Battery instructions A Identification Cover The cover identifies the battery to which the present Manuali s dedicated In the cover are indicated the following data Builder Logo Battery model Identification code Editorial date Version B Chapters Index The index of chapters numerates the subjects examined by the manual Analytical index develops...

Page 4: ...ted from NOT AUTHORIZED personnel declares the warranty NO MORE VALID Li ion batteries disposal The batteries signed with the recycling symbol must be treated from a separate collection of rubbish centre recognized from the recycling Agency The batteries must not be mixed togheter with domestic and industrial rubbish Use protective glasses in order to work with battery Not open or dismantle the ba...

Page 5: ...harge Terms for conservation e o off duty not respected Damages due to a wrong use to be more precise functioning limits overcoming see technical data schedale Deformation or breakage of the box Opening of the box Replacement of the screws present on the poles with others of different lenght Routine service or maintenance effected from NOT qualified personnel Use of battery charter maintainers NON...

Page 6: ...ndards for Commercial electronic Products EN 50082 1 1997 Low voltage Directive 2006 95 EC European Standard low Vooltage Directive EN 60950 2000 2 2 TECHNICAL FEATURES AND DIMENSIONS Litio Ion BATTERY 13 3 A Nominal voltage 13 2 V Nominal capacity 2 3 A h End charge max voltage 14 5 V End charge min voltage 8 V Discharge max current 5 secs 120 Amp Charge max current 8 Amp Max working temperature ...

Page 7: ...ENT LENGHT 3 4 BATTERY CHARGER Like all the Litio technology batteries ENERGA batteries must be charged with suitable battery chargers properly tested in the max current and max tension of end charge The battery charger must work in a CONSTANT CURRENT regime that must not exceed the max allowed recharge current look at the chapter TECHNICAL DATA max charge current until the reaching of the end cha...