14
5.
Performance Specifications
Unit may be improved or technical data may be modified without prior notice. For specific technical
parameters, please check the plate on the side of the unit.
5.1
Model ERHP-SU08
ITEM
UNIT
VALUE
Model range
ERHP-SU08-MS &
ERHP-SU08-SS
Refrigerant
R410a
Mass of Refrigerant
g
550
Compressor Discharge Pressure
Bar
23*
Compressor Suction Pressure
Bar
10*
Power Supply
– Voltage
V
220
–240/1ph
Power Supply
– Frequency
Hz
50
Heating Capacity
kW
3**
Average Rated Running Current
A
2.73***
Average Rated Power Input
kW
0.6***
Coefficient of Performance (COP)
W/W
3.33***
Electric Heater Rated Current
A
9
Electric Heater Rated Power Output
kW
2 ****
Water Temperature Setting Range
°C
30 ~ 55 ~ 75 *****
Maximum Water Temperature
°C
75
Highest Ambient Temperature
°C
45
Lowest Ambient Temperature
°C
-5
Water Tank Size
L
100
– 200
Maximum Water Pressure
Bar
7
Inlet and Outlet Water Pipe Diameter
Inch
3/4"
Protection against water class
IPX4
Noise Level
dBA
<55
Net Weight
kg
35-37
Net Dimension
w x d x h
778 x 320 x 504
Packing Dimension
w x d x h
820 x 415 x 510
Note:
* Testing condition:
Ambient Temperature:
20°C DB / 15°C WB
Water Inlet Temperature:
30°C
** Testing condition:
Ambient Temperature:
30°C DB
*** Testing condition:
Ambient Temperature:
20°C DB / 15°C WB
Water Heating Cycle:
15°C to 55°C
**** Heat pump output for backup element.
***** Water temperature can reach 55°C by the heat pump alone. However, if the desired
water temperature needs to go higher (56°C to 75°C) the electric heater will be activated.
FOR INFORMATION ONLY
Configuration Management
M-Tech Industrial (Pty) Ltd