184 mm
16
2 m
m
ePOWER Inverter DC Input Connection:
CAUTION
• Reversing the DC Input terminal will damage the unit and cannot be repaired. Damage caused by reverse
polarity connection is not covered by the warranty.
Hardwired Direct Connection:
•
Make sure the main fuse is not connected or breaker is switched off.
•
Attach a positive (+) DC terminal (red) cable on the power inverter.
•
Attach a negative (-) DC terminal (black) cable on the power inverter.
•
Tighten the nut on each DC terminal.
•
Connect the other end of the positive DC input cable to one of the terminals of the fuse holder or
circuit breaker switch.
•
Connect a DC positive input cable between the other terminals of the fuse holder or circuit breaker
switch to the battery positive terminal.
•
Connect the DC negative cable from the inverter to the Negative BUS of your DC System.
•
Install the selected fuse to the fuse holder or switch on the circuit breaker.
•
Unit is ready for use.
CAUTION
• Please be sure all the connections are tight before the use of the unit.