Battery Charger Voltage
Battery Type
Absorption
Float
Equalisation
GEL
14.4 V
13.7 V
N.A.
AGM
14.6 V
13.6 V
N.A.
Flooded
14.4 V
13.3 V
15.5 V (See Note1)
Lithium LiFeP04
Constant 13.9, 14.0, 14.1, 14.2, 14.3,
14.4, 14.5, 14.6 Volts (See Note2)
N.A
Program (Power Supply)
Constant 13.3, 13.5, 13.7 Volts (See Note3)
N.A
* For 24V model charger multiply above voltages by 2.
** For Concorde™ branded batteries (lifeline, sun x tender) use flooded setting and consult battery supplier for equalisation
recommendations
Note: Reference your Battery Manual for max charge current as this may differ
The battery charging current rating is based on the battery size. Each battery bank should meet the
minimum Ah rating as shown. If a smaller size battery bank is used, set the current rating to lower value
to match with the battery bank size. Normally, the minimum battery bank capacity is based on twice the
charger current rating.
EN31220
EN31240
EN31260
EN32430
Current
Setting
Battery
Capacity
Current
Setting
Battery
Capacity
Current
Setting
Battery
Capacity
Current
Setting
Battery
Capacity
5A
Min 10Ah
5A
Min 10Ah
5A
Min 10Ah
5A
Min 10Ah
10A
Min 20Ah
10A
Min 20Ah
20A
Min 40Ah
10A
Min 20Ah
15A
Min 30Ah
20A
Min 40Ah
40A
Min 80Ah
20A
Min 30Ah
20A
Min 40Ah
40A
Min 80Ah
60A
Min 120Ah
30A
Min 60Ah
Current
Setting
Battery
Capacity
Enerdrive Battery Charger Owners Manual Rev. 5.4
Note 1:
Equalisation setting can only be used on flooded battery type selection only. See more details
on Procedure to Equalise the Flooded Battery.
Note 2:
Charger will terminate charging when charging current drop to below the set charger
termination value (L setting).
Note 3:
Charger is acting as a power supply with selected constant output voltage and preset maximum
output current. With this setting, only Bank 1 can be used, Bank 2 and 3 is disabled.
Battery Bank Size Recommendation
EN312100
40A
Min 80Ah
60A
Min 120Ah
80A
Min 160Ah
100A
Min 200Ah
Summary of Contents for DOMETIC EN312100
Page 15: ...www enerdrive com au Page 15 Lead Acid Profile...
Page 38: ...Page 38 Enerdrive Battery Charger Owners Manual Rev 5 4...
Page 39: ...www enerdrive com au Page 39...
Page 40: ...Page 40 Enerdrive Battery Charger Owners Manual Rev 5 4...
Page 41: ...www enerdrive com au Page 41...