Enerco MR. HEATER MHVFB10LPI Installation Instructions And Owner'S Manual Download Page 10

10

Installation instructions and Owner’s Manual

Figure 16

CAUTION:

 Do not try to adjust heating level by using

equipment shutoff valve.

WARNING:

 When running heater, set control knob at

“LO” or “HI” locked positions.  Poor combustion and

higher levels of carbon monoxide may result if heater

is operated with control knob positioned between

locked positions.

IMPORTANT:

 Release downward pressure while turning

control knob.  Control knob must be locked at the

desired position.

TO TURN OFF GAS TO APPLIANCE

SHUTTING OFF HEATER:

1. Turn control knob clockwise to the OFF position.
2. Turn off equipment shutoff valve.

SHUTTING OFF BURNER ONLY (PILOT STAYS LIT)

1. Turn control knob clockwise to the PILOT/IGN

position.

INSPECTING  BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 17 show a correct pilot flame pattern.  Figure 22

shows an incorrect pilot flame pattern.  The incorrect

pilot flame pattern is not touching thermocouple.  This

will cause the thermocouple to cool.  When the thermo-

couple cools, the heater will shut down.  If pilot flame

pattern is incorrect, as shown in Figure 22:

Turn heater off (see 

To Turn OFF Gas to Appli-

ance

, page 10 for non-thermostat models).

See Troubleshooting, pages 12 and 13.

Figure 22

CLEANING AND MAINTENANCE

WARNING:

 Turn off heater and let cool before

servicing.

CAUTION:

 You must keep control areas, burner and

circulation air passageways of heater clean.  Inspect

these areas of heater before use. Have the heater

inspected yearly by a qualified service person.  Heater

may need more frequent cleaning due to excess lent

from carpeting, bedding material, pet hair, etc.

Control  Knob

 Figure 17

Summary of Contents for MR. HEATER MHVFB10LPI

Page 1: ...r service agency or the gas supplier WARNING This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provi sions for adequate combustion and ventilation air must...

Page 2: ...or anemia those under the influence of alcohol and those at high altitudes Propane LP Gas Propane LP gas is odorless An odor making agent is added to propane LP gas The odor helps you detect a Propan...

Page 3: ...r The information on pages 3 through 5 will help you classify your space and provide adequate ventilation Unusually Tight Construction If your home meets all of the three following criteria you must p...

Page 4: ...esh air Your options are as follows A Rework worksheet and the space of an adjoining room If the extra space provides an unconfined space remove door to adjoining room or add ventila tion grills betwe...

Page 5: ...ff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase a CSA AGA certified equipment shutoff valve from your dealer SeeAccessories page 17 This heater may also be ins...

Page 6: ...bracket to wall studs 1 Drill holes at marked locations using 9 64 drill bit 2 Place mounting bracket onto wall Line up holes on each end of bracket with hole drilled in wall 3 Insert mounting screws...

Page 7: ...ing gas pressure to between 11 and 14 inches of water If you do not reduce incoming gas pressure heater regulator damage could occur Install external regulator with the vent pointing down as shown in...

Page 8: ...S FOR USE WITH HOSE CONNECTED TO A REMOTE CYLINDER MAXIMUM SIZE 20 LBS This Heater may be used in a Recreational Enclosure or Temporary Construction Work Enclosure with a Remote Refillable Propane Cyl...

Page 9: ...is on 3 Push in gas control knob and slightly turn clockwise to the OFF position see figure 16 Note Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 4 Wait five 5...

Page 10: ...ck pilot flame pattern and burner flame pattern often PILOT FLAME PATTERN Figure 17 show a correct pilot flame pattern Figure 22 shows an incorrect pilot flame pattern The incorrect pilot flame patter...

Page 11: ...should also be followed 1 Shut off the unit including the pilot Allow the unit to cool for at least thirty minutes 2 Inspect burner and pilot for dust and dirt 3 Blow air through the port slots and ho...

Page 12: ...d 1 Burner orifice is clogged 2 Burner orifice diameter to small 3 Inlet gas pressure is too low 1 Manifold pressure is too low 2 Burner orifice is clogged When Piezo ignitor knob is turned there is n...

Page 13: ...line have gas line checked by local gas company 3 Observe minimum installation clearances see Figure 4 page 5 4 Clean burner orifice see Cleaning and Maintenance on page 11 or replace burner orifice...

Page 14: ...supply original replacement part s call Enerco Group Inc s 800 on the back of this manual TECHNICAL SERVICE You may have further questions about installation operation or troubleshooting if so contac...

Page 15: ...lector Front 1 8 70324 Valve Piezo Assembly 1 13 70357 Pressure regulator 1 14 70370 Steel Panel 1 15 70327 Steel Panel Mounting Bracket 1 16 70366 ODS Pilot Assembly 1 1 1 19 70396 Heat Shield Top 1...

Page 16: ...lacement parts Failure to use original factory parts voids this warranty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the un...

Reviews: