Enerco Group, Inc. | Convection Construction Heater

OPERATING PRECAUTIONS

This is a propane, direct-fired, convection heater. It's intended
use is primarily temporary heating of buildings under
construction, alteration or repair.

Propane is heavier than air. If propane leaks from a connection
or fitting, it sinks to the floor, collecting there with the
surrounding air, forming a potentially explosive mixture.
Obviously, propane leaks should be avoided, so set up the
propane supply with utmost care. Read enclosed Odor Fade and
Propane Sheet for additional information about detecting
propane leaks. Leak check new connections or reconnections
with a soap and water solution and follow all connection
instructions herein. Also, ask your propane dealer for advice on
the propane application and supply installation and ask him to
check it if there are any questions.

This heater was designed and certified for use as a construction
heater in accordance with ANSI Standard Z83.7/CGA 2.14-2000.
Check with your local fire safety authority if you have any
questions about your applications. Other standards govern the
use of fuel gases and heat producting products in specific
applications. Your local authority can advise you about these.

Direct-Fired means that all of the combustion products enter the
heated space. Even though this heater operates very close to 100
percent combustion efficiency, it still produces small amounts of
carbon monoxide. Carbon monoxide (called CO) is toxic. We can
tolerate small amounts but not a lot. CO can build up in a heated
space and failure to provide adequate ventilation could result in
death. The symptoms of inadequate ventilation are:

headache

dizziness

burning eyes and nose

nausea

dry mouth or sore throat

So, be sure to follow advice about ventilation in these operating
instructions.

When the heater is to be operated in the presence of other
people the user is responsible for properly acquainting
those present with the safety precautions and instructions,
and of the hazards involved.

SAFETY PRECAUTIONS

1.

Check the heater thoroughly for damage. DO NOT operate a
damaged heater.

2.

DO NOT

 modify the heater or operate a heater which has

been modified from its original condition.

3.

DO NOT 

light or operate heater unless the shells are fully

extended and locked into position.  See enclosed assembly
sheet for instructions.

4.

Use only propane gas.

5.

Use only VAPOR WITHDRAWAL propane supply. If there is
any question about vapor withdrawal, ask your propane
dealer.

6.

Mount the propane cylinders vertically (shutoff valve up).
Secure them from falling or being knocked over and protect
them from damage.

7.

Locate propane containers at least (USA) 7 ft. (2.13m)
for 80CV and 9 ft.  (2.7m) for 200CV (Canada)10 ft. (3m)
from the heater and 

do not

 direct exhaust toward

containers.

8.

IMPORTANT

 Use only the hose and regulator assembly

provided with the heater. Match the color stripe on the
hangtag attached to the hose assembly with the color on the
label located near the propane inlet fitting on the heater.
Inspect hose assembly before each use of the heater. If there
is excessive abrasion or wear, or hose is cut, replace with
hose assembly listed on parts list before using heater.

9.

For indoor use only. Area must be well ventilated. 

Figure 1

.

 (also see "Operating Precautions").

10. If at any time gas odor is detected, IMMEDIATELY

DISCONTINUE operation until the source of gas has been
located and corrected. Read enclosed Odor fade and
Propane Sheet for additional information about detecting
propane leaks.

11. Install the heater such that it is not directly exposed to water

spray, rain and/or dripping water.

12. Maintain minimum clearance from normal combustible

material (like paper). 

Figure 2

.

13. Due to the high surface and exhaust temperatures, adults

and children must observe clearances to avoid burns or
clothing ignition.

14. Operate only on a stable, level surface.
15. Do not use with duct work. Do not restrict inlet or exit.
16. Do not move, handle or service while hot or burning.
17. Use only in accordance with local codes or, in the absence of

local codes, with the Standard for the Storage and Handling
of Liquefied Petroleum Gases ANSI/NFPA 58 and CSA
B149.1, Natural Gas and Propane Installation Code.

Figure 1

VENTILATION: Minimum openings required

Opening

Opening

Heater

near floor

near ceiling

Convection 80CV, 200CV ................ 2 ft

2

..............................

2 ft

2

Figure 2

MINIMUM CLEARANCE: From normal combustible material

80CV, 200CV

Clearance

Convection

From sides .................................................. 4 ft

From top .................................................... 6 ft

Locate 10'  from canvas or plastic tarpaulins or similar coverings
and secure them to prevent flapping or movement due to wind
action.

Summary of Contents for HEATSTAR HS200CV

Page 1: ...may result causing property damage personal injury or loss of life WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cylin...

Page 2: ...STATE OF CALIFORNIA REQUIRES THE FOLLOWING WARNING WARNING COMBUSTION BY PRODUCTS PRODUCED WHEN USING THIS PRODUCT CONTAIN CARBON MONOXIDE A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER A...

Page 3: ...Toperatea damagedheater 2 DO NOT modify the heater or operate a heater which has beenmodifiedfromitsoriginalcondition 3 DONOTlightoroperateheaterunlesstheshellsarefully extendedandlockedintoposition S...

Page 4: ...person and the firefighters check for escaped gas Have them air out the building and area before you return Properly trained service people must repair any leaks check for further leakages and then re...

Page 5: ...IS HAPPENS THE SCREW HOLES WILL LINE UP STEP 4 LOCK THE CLIP INTO PLACE WITH 3 SCREWS AS SHOWN THE HEATER MUST NOT BE OPERATED UNLESS THE OUTER SHELL IS PROPERLY EXTENDED AND FULLY LOCKED INTO PLACE C...

Page 6: ...e heater is working properly The flame is contained within the heater The flame is essentially blue with perhaps some yellow tipping There is no strong disagreeable odor eye burning or other physical...

Page 7: ...proximate size of the cylinder required for these heaters To use the chart 1 Select the lowest air temperature expected at the bottom of the chart 2 Move straight up to time of operation desired left...

Page 8: ...PTx1 4 MPT 1 M8018 Fitting Adapter 1 8 FPT x 1 4 MPT 1 70486 Manual Operating Instructions 1 REF ITEM Description Qty 19 M6255 Regulator 1 20 M8654 Valve Ball 1 21 M6473 Piezo Ignitor 1 22 M6503 Nut H...

Page 9: ...Excell Flow 1 19 M6256 Regulator 1 REF ITEM Description Qty 20 M8654 Valve Ball 1 21 M6473 Piezo Ignitor 1 22 M6503 Nut Hex 1 2 28 TE Valve 1 23 M7172 Ftg Elbow Female 1 4 FPTx3 8 FLR 2 24 M8162 Exte...

Page 10: ...ed our product The foregoing is the full extent of the responsibility of the Company There are no other warranties express or implied Specifically there is no warranty of fitness for a particular purp...

Reviews: