background image

14

Enerco | Catalytic Heater

Operating Instructions and Owner’s Manual

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

Enerco Group, Inc. reserves the right to make changes at any time, without notice or obligation, in colors, specifications, 

accessories, materials and models.

PRODUCT REGISTRATION:  Thank you for your purchase.  
Please log in to http://www.egiregistration.com to register your product.

This product is covered by one or more patents/patents pending.  Please visit 
http://www.enercogroupinc.com/patents for more information.

WARRANTY AND PARTS ORDERING

Enerco Group, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 888-849-1899

Enerco is a registered trademark of Enerco Group, Inc.

© 2019, Enerco. All rights reserved

Model # ECAT3LP • ECAT6LP • ECAT8LP

PARTS ORDERING INFORMATION

PURCHASING: 

Accessories may be purchased at any Enerco local dealer or direct from the factory 

FOR INFORMATION REGARDING SERVICE

Please call Toll-Free 888-849-1899

Or visit www.enerco.com

Our office hours are 8:00 AM – 5:00 PM, EST, Monday through Friday.

Please include the model number, date of purchase, and description of problem in all communication.

LIMITED WARRANTY

Enerco Group, Inc. warrants its heaters and accessories to be free from defects in material and workmanship for a period of 
1 year from date of purchase. Enerco Group, Inc. will repair or replace this product free of charge if it has been proven to be 
defective within the 1-year period, and is returned at customer expense with proof of purchase to Enerco Group, Inc. within 
the warranty period. DISCLAIMER: This warranty does not cover any product that: a) has been subject to misuse or neglect; b) 

has been used in a manner inconsistent with the warnings and instructions contained in the owner’s manual, including but not 

limited to using a heater for the cooking or warming of foods; or c) has been used with hand-made or third party accessories 
or attachments. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

WARNING:

 

USE  ONLY  MANUFACTURER’S  REPLACEMENT  PARTS.  USE  OF  ANY  OTHER  PARTS  COULD  CAUSE  INJURY  OR  DEATH. 

REPLACEMENT PARTS ARE ONLY AVAILABLE DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE 
AGENCY. ENERCO HOSES 

F271161

F271161-60

 AND 

F271161-144

 ARE SPECIFICALLY DESIGNED FOR USE WITH THIS HEATER 

ALONG WITH 

F273699

. USE OF OTHER HOSES MAY CAUSE THE HEATER TO BECOME INOPERABLE.

WARNING:

THIS PRODUCT IS A HEATER.  IT IS CERTIFIED TO ANSI STANDARD Z21.103, “

UNVENTED PORTABLE TYPE GAS CAMP HEATERS

FOR INDOOR AND OUTDOOR USE

.”

 THIS PRODUCT IS 

NEVER

 TO BE USED FOR THE COOKING OR WARMING OF FOODS 

AS DOING SO CAN INTERFERE WITH THE SAFETY SYSTEMS OF THE HEATER, WHICH MAY RESULT IN A FIRE, EXPLOSION, 

THE PRODUCTION OF DEADLY CARBON MONOXIDE, AND PERSONAL INJURY OR DEATH TO YOU OR OTHERS.  

NEVER

 USE 

HAND-MADE OR THIRD PARTY ACCESSORIES OR ATTACHMENTS WITH THIS HEATER; THIS IS EXTREMELY DANGEROUS AND 

MAY RESULT IN PERSONAL INJURY OR DEATH TO YOU OR OTHERS.

Summary of Contents for ECAT3LP

Page 1: ...ately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department or a qualified service agency Installation an...

Page 2: ...fuel supply 4 Leave the area immediately 5 Allow gas to dissipate 5 minutes before relighting the appliance Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this o...

Page 3: ...le 4 x 2 opening 3 x 2 opening and 3 x 1 opening respectively at the ceiling and at floor level for adequate ventilation during operation Do not use other fuel burning appliances inside GAS PRESSURE A...

Page 4: ...ane LP gas odor may differ in intensity at different levels Since propane LP gas is heavier than air there may be more odor at lower levels Always be sensitive to the slightest gas odor If you continu...

Page 5: ...by a qualified service person The heater should be inspected before use and at least annually by a professional service person WARNING Any change to this heater or its controls or attempts to clean th...

Page 6: ...thsoapywateratthethreaded connection on the side of the heater DO NOT USE ANY EXPOSED FLAME TO CHECK FOR LEAKS DO NOT OVERTIGHTEN Wall Installation Your heater may be installed in a variety of fixed l...

Page 7: ...eterioration are all possible causes 2 The heater has been allowed time to cool down completely 3 It has been determined that there is no leaked or otherwise unburned propane LP gas present in the sur...

Page 8: ...ouple The flame will surround the thermocouple just below the tip Figure 6 shows a correct pilot flame pattern and also shows an incorrect pilot flame pattern The incorrect pilot flame pattern is not...

Page 9: ...or 14 mm wrench to remove the compression nut connecting the inlet gas tube to the enclosure See Figure 1 1 4 Lift up on the control bracket assembly to remove it from the heater See Figure 12 5 Compl...

Page 10: ...Refer to Figure 4 in the Installation section on page 6 to replace the feet OFFSEASON If the heater is to left OFF for a considerable period of time the propane LP gas supply to the heater should be...

Page 11: ...ve contamination 5 Replace control valve SYMPTOM Spark electrode produces spark but pilot does not light CAUSE REMEDY 1 No gas to heater 1 Connect hose to heater and turn on valve at remote cylinder 2...

Page 12: ...acket 1b 36834 36834 36834 Handle grip 2 36832 36832 36832 Burner Access Panel 3 36818 36818 36818 Lower Access Panel 4 36817 36817 36817 Foot 5 78436 78436 78436 Foot Pad Rubber 6 32123 32123 32123 V...

Page 13: ...ing Instructions and Owner s Manual Enerco Catalytic Heater NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDED WHILE BURN...

Page 14: ...is product free of charge if it has been proven to be defective within the 1 year period and is returned at customer expense with proof of purchase to Enerco Group Inc within the warranty period DISCL...

Page 15: ...iales lesiones o muertes No almacene ni utilice gasolina ni ning n otro vapor ni l quido inflamable cerca de este ni de ning n otro artefacto QU HACER SI DETECTA OLOR A GAS No intente encender el arte...

Page 16: ...mediatamente el rea 5 Permita que el gas se disipe durante 5 minutos antes de volver a encender el artefacto No almacene ni utilice gasolina ni ning n otro vapor ni l quido inflamable cerca de este ni...

Page 17: ...emplo una abertura de 4 x2 3 X2 y 3 x1 respectivamente en el techo y al nivel del piso para una ventilaci n adecuada durante su funcionamiento No use otros electrodom sticos que queman combustible en...

Page 18: ...ibiendo el olor a gas no importa cu n poco sea proceda como si fuera una fuga seria Tome medidas inmediatamente como se explic anteriormente ATENCI N PUNTOS IMPORTANTES A RECORDAR El gas propano LP ti...

Page 19: ...ejados para evitar quemaduras o quemaduras en la ropa Los ni os peque os deben estar vigilados cuidadosamente cuando est n en la habitaci n en donde se encuentre el calefactor No coloque ropa u otro m...

Page 20: ...conecte el otro extremo de la manguera a la v lvula del cilindro de suministro de gas propano LP o al punto de conexi n Apriete todas las conexiones de la manguera NO use sellador de roscas en ninguna...

Page 21: ...a del regulador falla mec nica del calefactor o deterioro de la almohadilla catal tica hayan sido todas las causas posibles 2 Se haya permitido que el calefactor se enfr e por completo 3 Se haya deter...

Page 22: ...correcto y tambi n muestra un patr n de llama piloto incorrecto El patr n de llama piloto incorrecto no est tocando la termocupla Esto har que se enfr e la termocupla Cuando la termocupla se enfr e el...

Page 23: ...ipal del calefactor Consulte la Figura 10 2 Remueva la perilla de la v lvula separ ndola del calefactor 3 Use una llave de 9 16 o de 14 mm para remover la tuerca de compresi n que conecta el tubo de g...

Page 24: ...a almohadilla Siga los pasos para reemplazar el quemador cuando tenga que reemplazar la almohadilla catal tica Reemplazo de las patas Consulte la Figura 4 en la secci n Instalaci n de la p gina 6 para...

Page 25: ...a de control S NTOMA El electrodo de encendido produce chispa pero el piloto no se enciende CAUSA SOLUCI N 1 No llega gas al calefactor 1 Conecte la manguera al calefactor y abra la v lvula en el cili...

Page 26: ...6834 36834 36834 Manija mango 2 36832 36832 36832 Panel de acceso al quemador 3 36818 36818 36818 Panel de acceso inferior 4 36817 36817 36817 Pata 5 78436 78436 78436 Almohadilla para pata goma 6 321...

Page 27: ...13 S Instrucciones de uso y manual del usuario Enerco Calefactor catal tico NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NUNCA DEJE EL CALEFACTOR DESATENDIDO MIENTRAS EST ENCENDIDO NOTAS...

Page 28: ...r a o tras realizada la compra siempre y cuando el cliente costee la devoluci n y presente el comprobante de compra a Enerco Group Inc dentro del per odo de garant a DESCARGO DE RESPONSABILIDAD Esta g...

Reviews: