background image

 
 
 
 
 
 
 

1. Dust ring with water jacket 

on the vacuum. 

2. Removing the heat pipe 

header 20-30CM. 

3. Evenly coated with thermal 

glue on the condenser. 

 
 
 
 
 
 
 

4. Vacuum tube tail into the 

pipe supports from top to 

bottom. 

5. Holding the heat pipe forced 

into socket on the tank. 

6. Vacuum tube inserted into 

the tank according with the 

heat pipe. 

 
 
 
 
 
 
 

7. Turn the tube holder to be 

tightly (to keep vacuum tube 

could not be moved up and 

down ) 

8. The tank angle is fine-tuning, 

and screw fastening on the tank 

bottom. 

9. Slide the dust ring on the 

proper position, then assemble 

the CPC reflectors. 

The new pressurized solar water heater, the cold water inlet connect with city water directly, Can withstand high pressure when 

it works.(Means if the cold water supply pressure in stable, when open the outlet valve will

have hot water in time with same pressure;)

Attention (importance):

1.  During  the  storm  with  lightening,  please  DO  NOT  use  solar  water  heater  and  keep  the  tank  full  of  water  during  the 

typhoon/hurricane;

2. In the summer, if hot water not much used or water temperature is so high, please take some shade to cover part of vacuum 

tube to reduce the heating; This solar water heater can be used around the clock throughout the year; service life over 15 years; 

During this period, you can perform some simple maintenance work:

1. Clean the vacuum tubes:

If dust or dirt on the vacuum tubes is too dense, it will reduce the reflection rate for a long time. Thus, you need to clean the 

vacuum tubes at least once every six months or a year, depending on the conditions of contamination. You can use soapy water 

or water with cleaning products to clean the vacuum tubes.

2. Monitor the condition of the solar water heater:

Poor water in some areas can lead to accumulation of scale in the tank or failure of safety valves, which will affect the efficiency 

of  the  solar  heater  or  its  breakage.  Thus,  you  should  visually  inspect  the  system,  check  the  operation  of  the  valves  and,  if 

necessary,  but  not  less  than  once  every  two  years,  ask  a  specialist  to  replace  wornout  connections  and  parts,  such  as  a 

magnesium anode, valves and an electric heater.

Special warning

1. Installing the water heater must be caution of on the high position what required of a professional 

installer operation, pay attention to their personal safety!

2. Transportation and installation, gently especially for the fragile glass tubes

3. Before installation, please carefully read the installation instructions in strict accordance with the 

manual operation, and by the professional installation. Otherwise the improperly installed may lead 

to  serious  personal  injury  and  property  damage,  the  installation  is  divided  into  four  parts:  frame 

installation, tank installation and tubes installation and connection of the water heater piping.

FRAME MOUNTING

Solar  water  heater  should  be  in  the  sunny  square,  ideally  correct  location  -  facing  south.  Use 

galvanized  iron  wire  or  expansion  screws  or  cement  and  fixed  the  roof  pad  bracket  under  hard 

objects.

PIPELINE CONNECTIONS

 Connect the water pipe line , try to use the special composite pipe or cross-linked pipe, to reduce the

water rust and heat loss, piping using insulation materials the better is fixed on the stand or building, 

if in the cold areas, drain valve can be added, so the emptying of the water in the pipe line.

INTRODUCTION

The T/P exhaust port stringent blockage. It should have received an 

additional exhaust pipe to prevent the tank internal pressure is too 

high splash hot water to cause damage to persons and property.

1- Inlet ; 2- Outlet ; 3- Electric Heater ; 4- Magnesium Bar ; 

5- Temperature Sensor ; 6- T/P Valve ; 7- Controller

USER INSTRUCTIONS

INSTALLATION OPTIONS

Placement of water heaters can be selected according 

to user requirements

Solar water heater can be connected more than in series,

parallel way into the collective hot water system.

TANK INSTALLATION

Put the tank on the tank support after the frame 

completed assembly. Place the four screw bolts on the 

tank into the tank support, but let the screws not to be 

turned tightly temporarily. Please pay attention to the 

direction of vacuum tube hole to be the same angle 

direction with the tube holder on the bottom track 

(manifold). Fix the tube holders on the bottom track then 

turn down its male part.