1. Dust ring with water jacket
on the vacuum.
2. Removing the heat pipe
header 20-30CM.
3. Evenly coated with thermal
glue on the condenser.
4. Vacuum tube tail into the
pipe supports from top to
bottom.
5. Holding the heat pipe forced
into socket on the tank.
6. Vacuum tube inserted into
the tank according with the
heat pipe.
7. Turn the tube holder to be
tightly (to keep vacuum tube
could not be moved up and
down )
8. The tank angle is fine-tuning,
and screw fastening on the tank
bottom.
9. Slide the dust ring on the
proper position, then assemble
the CPC reflectors.
The new pressurized solar water heater, the cold water inlet connect with city water directly, Can withstand high pressure when
it works.(Means if the cold water supply pressure in stable, when open the outlet valve will
have hot water in time with same pressure;)
Attention (importance):
1. During the storm with lightening, please DO NOT use solar water heater and keep the tank full of water during the
typhoon/hurricane;
2. In the summer, if hot water not much used or water temperature is so high, please take some shade to cover part of vacuum
tube to reduce the heating; This solar water heater can be used around the clock throughout the year; service life over 15 years;
During this period, you can perform some simple maintenance work:
1. Clean the vacuum tubes:
If dust or dirt on the vacuum tubes is too dense, it will reduce the reflection rate for a long time. Thus, you need to clean the
vacuum tubes at least once every six months or a year, depending on the conditions of contamination. You can use soapy water
or water with cleaning products to clean the vacuum tubes.
2. Monitor the condition of the solar water heater:
Poor water in some areas can lead to accumulation of scale in the tank or failure of safety valves, which will affect the efficiency
of the solar heater or its breakage. Thus, you should visually inspect the system, check the operation of the valves and, if
necessary, but not less than once every two years, ask a specialist to replace wornout connections and parts, such as a
magnesium anode, valves and an electric heater.
Special warning
:
1. Installing the water heater must be caution of on the high position what required of a professional
installer operation, pay attention to their personal safety!
2. Transportation and installation, gently especially for the fragile glass tubes
3. Before installation, please carefully read the installation instructions in strict accordance with the
manual operation, and by the professional installation. Otherwise the improperly installed may lead
to serious personal injury and property damage, the installation is divided into four parts: frame
installation, tank installation and tubes installation and connection of the water heater piping.
FRAME MOUNTING
Solar water heater should be in the sunny square, ideally correct location - facing south. Use
galvanized iron wire or expansion screws or cement and fixed the roof pad bracket under hard
objects.
PIPELINE CONNECTIONS
Connect the water pipe line , try to use the special composite pipe or cross-linked pipe, to reduce the
water rust and heat loss, piping using insulation materials the better is fixed on the stand or building,
if in the cold areas, drain valve can be added, so the emptying of the water in the pipe line.
INTRODUCTION
The T/P exhaust port stringent blockage. It should have received an
additional exhaust pipe to prevent the tank internal pressure is too
high splash hot water to cause damage to persons and property.
1- Inlet ; 2- Outlet ; 3- Electric Heater ; 4- Magnesium Bar ;
5- Temperature Sensor ; 6- T/P Valve ; 7- Controller
USER INSTRUCTIONS
INSTALLATION OPTIONS
Placement of water heaters can be selected according
to user requirements
Solar water heater can be connected more than in series,
parallel way into the collective hot water system.
TANK INSTALLATION
Put the tank on the tank support after the frame
completed assembly. Place the four screw bolts on the
tank into the tank support, but let the screws not to be
turned tightly temporarily. Please pay attention to the
direction of vacuum tube hole to be the same angle
direction with the tube holder on the bottom track
(manifold). Fix the tube holders on the bottom track then
turn down its male part.