background image

INSTALLATION MANUAL

w

w

w

.ene
ra-sola

r.c

om

ENERA

High-Pressure Thermosiphon with System «Heat-Pipe»

SYSTEM SPECIFICATIONS

STRUCTURE

TROUBLESHOOTING

REASON

SOLUTION

PRO

1. Manifold

2. Front track

3. Side rod

4. Tank support

5. Front tie rod

6. Support leg

7. Across rod

8. Fixed triangle

9. Anti-wind feet

10. Tank

11. Vacuum tube

12. Tube holder

13. CPC reflector

14. Reflector handle

outlet

back

slope roof

flat roof

electric heater cover

temperature sensor

T/P valve magnesium stick

inlet

drain outlet

Principal Machine

Absorber

Tank material: stainless steel

Vacuum tube: Φ 58mm×1800mm

Working pressure: 6 Bar
Daily hot water temperature: 45-90

*C

Insulation: Polyurethane foam
Heat preservation: 72 hours 
Outer tank material: PVDF 
Frame: Thicker galvanized steel 

Vacuum degree: ≤5×10-3pa
Absorbing coating property: ≥0.93
Emission ratio: ≤0.08
Transition temperature: ≤25

*C

Tube stagnation parameters: 230*C
Freezing resistance: -40*C
Wind resistance: 30m/s( 11 force)
Lifetime : ≥15 year
Hail resistance: 35mm
Glass material: High borosilicate 3.3 glass 
Heat pipe: TU1
Condenser size: 14mm*65mm 
Vacuum tube size(mm): Φ 58×1800mm

Sunny day, 

no hot water

No hot water

in winter

The  front  of  solar  water  heaters  have 
occluder, high tower, trees, tall buildings, 
fences  or  other  water  heaters,  short 
sunshine ,causing the water temperature 
is low.
1. Vacuum tube surface have thick dust.
2. Hot outlet valves got leakage or can`t 
closed well.
3. Vacuum tube or heat pipe damaged.
4. The T/P valve on the main water tank 
can`t closed which cause the water keep 
flowing
Remove  the  occluder  or  move  the  solar 
water  heaters  to  the  place  without 
occluder

1. Cleaning the tube surface and reflector.
2. Check the valves.
3. Replace tube or heat pipe.
4. Check T/P valve.

1. Pipelines freezes in winter time (Cold area 
winter is not normal; sometimes to freeze in 
the morning, after sun defrost in afternoon).
2. Weather is too cold

1.  The  whole  pipeline  use  heat  pipe 
preservation
2.  Use  electric  heating  belt  together  with 
water  pipe  lines,  outside  with  heat  pipe 
preservation.

www.enera-solar.com

Partida el Planet 208 | 03590 Altea

MORE INFO & HELP

Email ENERA:

Call ENERA:

F.A.Q:

Manuals:

Warranty:

[email protected]

+34 634 799 310

www.enera-solar.com/faq/

www.enera-solar.com/download/

www.enera-solar.com/warranty-terms/ 

WARRANTY

- The warranty of all installed equipment is 2 years

- This period is valid if the magnesium corrosion anode is replaced every 12 month

- In the long-term non-use of the solar heater, it is recommended to close the cold water 

supply to the system for more than 72 hours

- The system must only be started when there is no sun 

- That is, during the morning or the night

- Filling the tank during the day leads to its failure, the guarantee would NOT be valid

WARRANTY CARD

System: 

Installation Date:

- STAMP -

(Client) Sign to Approve

Reviews: