INSTALLATION MANUAL
w
w
w
.ene
ra-sola
r.c
om
ENERA
High-Pressure Thermosiphon with System «Heat-Pipe»
SYSTEM SPECIFICATIONS
STRUCTURE
TROUBLESHOOTING
REASON
SOLUTION
PRO
1. Manifold
2. Front track
3. Side rod
4. Tank support
5. Front tie rod
6. Support leg
7. Across rod
8. Fixed triangle
9. Anti-wind feet
10. Tank
11. Vacuum tube
12. Tube holder
13. CPC reflector
14. Reflector handle
outlet
back
slope roof
flat roof
electric heater cover
temperature sensor
T/P valve magnesium stick
inlet
drain outlet
Principal Machine
Absorber
Tank material: stainless steel
Vacuum tube: Φ 58mm×1800mm
Working pressure: 6 Bar
Daily hot water temperature: 45-90
*C
Insulation: Polyurethane foam
Heat preservation: 72 hours
Outer tank material: PVDF
Frame: Thicker galvanized steel
Vacuum degree: ≤5×10-3pa
Absorbing coating property: ≥0.93
Emission ratio: ≤0.08
Transition temperature: ≤25
*C
Tube stagnation parameters: 230*C
Freezing resistance: -40*C
Wind resistance: 30m/s( 11 force)
Lifetime : ≥15 year
Hail resistance: 35mm
Glass material: High borosilicate 3.3 glass
Heat pipe: TU1
Condenser size: 14mm*65mm
Vacuum tube size(mm): Φ 58×1800mm
Sunny day,
no hot water
No hot water
in winter
The front of solar water heaters have
occluder, high tower, trees, tall buildings,
fences or other water heaters, short
sunshine ,causing the water temperature
is low.
1. Vacuum tube surface have thick dust.
2. Hot outlet valves got leakage or can`t
closed well.
3. Vacuum tube or heat pipe damaged.
4. The T/P valve on the main water tank
can`t closed which cause the water keep
flowing
Remove the occluder or move the solar
water heaters to the place without
occluder
1. Cleaning the tube surface and reflector.
2. Check the valves.
3. Replace tube or heat pipe.
4. Check T/P valve.
1. Pipelines freezes in winter time (Cold area
winter is not normal; sometimes to freeze in
the morning, after sun defrost in afternoon).
2. Weather is too cold
1. The whole pipeline use heat pipe
preservation
2. Use electric heating belt together with
water pipe lines, outside with heat pipe
preservation.
www.enera-solar.com
Partida el Planet 208 | 03590 Altea
MORE INFO & HELP
Email ENERA:
Call ENERA:
F.A.Q:
Manuals:
Warranty:
+34 634 799 310
www.enera-solar.com/faq/
www.enera-solar.com/download/
www.enera-solar.com/warranty-terms/
WARRANTY
- The warranty of all installed equipment is 2 years
- This period is valid if the magnesium corrosion anode is replaced every 12 month
- In the long-term non-use of the solar heater, it is recommended to close the cold water
supply to the system for more than 72 hours
- The system must only be started when there is no sun
- That is, during the morning or the night
- Filling the tank during the day leads to its failure, the guarantee would NOT be valid
WARRANTY CARD
System:
Installation Date:
- STAMP -
(Client) Sign to Approve