Eneo VKC-1356/AK Installation And Operating Instructions Manual Download Page 3

Installation and Operating Instructions

VKC-1356/AK
Camera Connection Box, weatherproof,  

for VKC-1356/IR

2.  General Description

•  Camera Wall Mount Connection Box
•  Mains Voltage Connection and Remote Supply
•  Control and Measurement Point
•  2 pin Video Signal Terminal and RS-485 Interface
•  6 pin Screw Terminal for Video and Control
•  Di-cast Aluminium Casing with 2 Cable Glands
•  Protection Rating: IP65
•  Accessories: Cable MCAB-2, Thread Adapter 3/4”

3.  Installation

1.  Safety Instructions / Maintenance

•   Read these safety instructions and the operation manual first before you 

install and commission the unit. 

•  Keep the manual in a safe place for later reference.
•   The system may only be commissioned and maintained by personnel  

authorized to do this and it must only be carried out in accordance with 
relevant standards and guidelines.

•   Protect your unit from contamination with water and humidity to prevent it 

from permanent damage. Never switch the unit on when it gets wet.  
Have it checked at an authorized service center in this case.

•   Never operate the units outside of the specifications as this may prevent 

their functioning.

•   Do not operate the unit beyond their specified temperature, humidity or po-

wer ratings. Operate the unit only at a temperature range of 0°C to +50°C 
and at a humidity of max. 80%.

•   The unit should be protected against excessive heat, dust, damp and  

vibration.

•   To disconnect the power cord of the unit, pull it out by the plug.  

Never pull the cord itself.

•   Pay attention when laying the connection cable and observe that the cable 

is not subject to heavy loads, kinks, or damage and no moisture can get in.  
Do not attempt to disassemble the camera board from the dome.

•  Contact your local dealer in case of malfunction.
•   Maintenance and repair have to be carried out only by authorized service 

centers. 

  Before opening the cover disconnect the unit from mains input.
•   The warranty becomes void if repairs are undertaken by unauthorized 

persons. Do not open the housing. 

•  The connection cable should only be changed by Videor E. Hartig GmbH.
•  Only use original parts and original accessories from Videor E. Hartig GmbH.
•   Do not use strong or abrasive detergents when cleaning the dome.  

Use a dry cloth to clean the dome surface. In case the dirt is hard to remove, 
use a mild detergent and wipe gently.

•  During assembly, care must be taken to ensure that existing seals are  
  correctly inserted and are not displaced as a result of assembly. 
  You must not continue to use damaged seals.

NOTE:  This is a class A digital device.  

This digital device can cause harmful interference in a residential 
area; in this case the user may be required to take appropriate 
corrective action at his/her own expense.

Anchor screw

•  Using the guide pattern as a template, cut a round opening the wall.
•   Drill four holes according to the guide pattern, then insert anchor screws 

into the drilled holes.

•  Fix the junction box to a wall using four anchor screws.
•   Camera cables go through Holder Grand on the front of the junction box, 

and fix them by 4 screws.

4  Connection to Camera Controller

A Type Model (Power/Video) 

     B Type Model (Power/Video/RS-485)

1

2

3

4

5

6

1

2

3

4

5

6

No. Wire Colour

Function

1

Red

12VDC

2

Orange

GND

3

Black

GND (Video)

4

Yellow

Video Out

5

Green

Not used

6

Brown

Not used

No. Wire Colour

Function

1

Red

12VDC

2

Orange

GND

3

Black

GND (Video)

4

Yellow

Video Out

5

Green

RS-485 (+)

6

Brown

RS-485 (–)

Reviews: