30
• VIEW ANGLE SETUP
VIEW ANGLE SETUP
PANNING RANGE
FLIP : 90
°
TILT ANGLE LIMIT : 10
°
SAVE AND EXIT(ESC TO CANCEL)
FLIP
OFF, AUTO, 90
°
, 100
°
, 110
°
, 120
°
OFF:
The dome camera moves until 90
°
vertically.
AUTO:
When the camera reaches the floor directly above the moving object, it will stop.
At that time, release the
Joystick
instantly and pull it down again to run the auto-flip
function. When you use the panning range, it is recommended to use the flip mode to AUTO.
90
°
, 100
°
, 110
°
, 120
°
:
Allows the image to flip digitally when the camera moves over the
setting angle vertically.
TILT ANGLE LIMIT
0
°
~ 10
°
This option is designed to limit the view angle as there is some obstruction in zooming out on
specific areas of the tilt angle.
NOTE:
Focus issues may occur in certain conditions.
PANNING RANGE
When the dome camera is installed near a wall, panning range can be limited by user.
PANNING RANGE SETUP
(CTRL KEY)
RIGHT LIMIT : 000.0
LEFT LIMIT : 000.0
ENABLE : OFF
SWAP : OFF
AUTO PAN : ON
SAVE AND EXIT(ESC TO CANCEL)
1. Place the dome camera under 90 degree vertically.
2. Set “
RIGHT LIMIT
” by pushing the
Joystick
to the right.
3. Set “
LEFT LIMIT
” by pushing the
Joystick
to the left.
4. Set “
ENABLE
” to ON to use.
To exchange the right and the left limit, set “
SWAP
” to ON.
To apply limits on the auto pan (endless panning), set “
AUTO PAN
” to ON.
NOTE: When the flip mode is 90
°
, 100
°
, 110
°
or 120
°
and you moves over 90
°
vertically,
the panning range operates in opposite side.
Summary of Contents for TPP-62A0012M0A