Safety instructions 

General safety instructions

•  Before switching on and operating the system, first read this safety advice and the operating instructions.

•  Keep the operating instructions in a safe place for later use. 

•   Installation, commissioning and maintenance of the system may only be carried out by authorised 

individuals and in accordance with the installation instructions - ensuring that all applicable standards and 

guidelines are followed. 

•  Protect the devices from water penetration and humidity, since these can cause lasting damage. 

•  Should moisture nevertheless enter the system, under no circumstance switch on the devices under these 

conditions, instead send them for examination to an authorised specialist workshop. 

•  The system must never be used outside of the technical specifications, since this can destroy it. 

•  The device must be protected from excesses of heat, dust, humidity and vibration. 

•  When separating the system from the voltage supply, only ever use the plug to pull out the cable. Never 

pull directly on the cable itself. 

•  Lay the connecting cables carefully and check that they are not mechanically stressed, kinked or damaged 

and that no humidity can penetrate into them. 

•  In the event of a malfunction, please inform your supplier. 

•  Maintenance and repairs may only be carried out by authorised specialist personnel. 

•  The system must be isolated from the power supply before opening the housing. 

•  The device may only be opened by qualified service personnel. Unauthorised access invalidates any 

warranty claim. 

•  Connection cables should always be exchanged through Videor E. Hartig GmbH. 

•  Use only original spare parts and accessories from Videor E. Hartig GmbH. 

•  The housing should only be cleaned using a mild domestic cleaning agent. Never use solvents or petrol as 

these can permanently damage the surface. 

•  During installation, it is essential to ensure that the seals provided are correctly installed and that they are 

not displaced during installation. Damaged seals must not be installed and will invalidate any warranty. 

•  The installer is responsible for the maintenance of the enclosure as per the technical data, e.g. by sealing 

the cable outlets with silicone.  

•  Wire end ferrules should be used when shortening the flexible connection cables. 

•  The devices may only be operated in the temperature range indicated in the data sheet and within the 

defined air humidity range. 

Product - Specific Safety Instructions

•  The camera may never be pointed directly at the Sun with the aperture open (this will destroy the sensor).

•  It is unavoidable that during manufacture and to a certain extent during later use, humidity will be present 

in the ambient air within the device’s housing. In the event of large temperature fluctuations, this humidity 

may condense inside the housing.

•  To avoid this condensation inside the very tightly sealed housing, the manufacturer has inserted silica gel 

sachets in the housing of the various camera types.

•  It is however a physical given, that these silica gel bags will reach saturation after a certain amount of time. 

They should therefore be replaced with new silica gel sachets.

•  During installation, it is essential to ensure that the seals provided are correctly installed and that they are 

not displaced during installation. Damaged seals must not be installed and will invalidate any warranty.

•  A multipolar, easily accessible isolation device should be installed in the proximity of the IR Spotlight, in 

order to disconnect the device from the power supply for service work. 

•  The earth connection must be made according to the low impedance requirement of DIN VDE 0100.

•  Subsequent painting of the equipment surface can impair the function.

•  Any warranty claim is invalidated by subsequent painting.

•  A safety margin of > 1m from the spotlight must be maintained when viewing directly into the IR Spotlight 

in a darkened environment.

•  Do not look directly at invisible LED radiation using optical instruments (e.g. a reading glass, magnifying 

glass or microscope), since this can endanger the eyes, LED Class 1M.

•  Operation of the IR spotlight with a defective cover or during repair is prohibited. 

Summary of Contents for ISM-62F0028W0A

Page 1: ...EN Quick Installation Guide 1 2 8 Network Board Camera Day Night WDR H 265 PoE 12VDC ISM 62F0028W0A ISM 65F0028W0A ISM 68F0028W0A DE...

Page 2: ...of content Components 5 Overview 6 Extension Cable 6 Connection 6 Installation monitor 6 Connecting with power supply 7 Connecting to the network 7 Quick Network Setup 8 Live Screen 9 Further informa...

Page 3: ...tallation Damaged seals must not be installed and will invalidate any warranty The installer is responsible for the maintenance of the enclosure as per the technical data e g by sealing the cable outl...

Page 4: ...waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer whe...

Page 5: ...ing components Camera Quick Guide RJ45 Waterproof Accessory Cable Joint Block Silica Gel i Notice Check your package to make sure that you received the complete system including all components listed...

Page 6: ...r Jack_RED DC12V IN Used to connect to a DC power cable 3 Alarm In Connect alarm in signal 4 Alarm Out Connect alarm out signal 5 Network Used to connect to the PoE Switch and network 6 Audio In Jack_...

Page 7: ...number in Network Setup screen 4 Enter your ID and password to log in You can watch the monitoring screen after login i Notice You must register your login password when accessing for the rst time To...

Page 8: ...CP server present in the net work the camera will fall back to a default IP address after a while In this scenario please only add one camera at a time to the network to avoid conflicts due to identic...

Page 9: ...o the camera by using a microphone connected to a PC 9 Snapshot Saves current image as jpg image le 10 Print Prints current screen 11 Panic Record Start the panic recording 12 Alarm Turns on if an eve...

Page 10: ...erms please refer to the open source information included in your products user interface the product detail pages on the eneo website www eneo security com the eneo download portal https datacloud vi...

Page 11: ...mponenten 14 bersicht 15 Verl ngerungskabel 15 Verbindung 15 Installationsmonitor 15 Anschlie en an die Stromversorgung 16 Anschluss an das Netzwerk 16 Schnelle Netzwerkkonfiguration 17 Live Ansicht 1...

Page 12: ...utzen dies kann die Oberfl che dauerhaft sch digen Bei der Montage muss grunds tzlich darauf geachtet werden dass vorhandene Dichtungen ordnungs gem eingesetzt und bei der Montage nicht verschoben wer...

Page 13: ...seiner Dokumentation gezeigte Symbol bedeutet dass es am Ende seiner Lebensdauer nicht mit dem Hausm ll entsorgt werden darf Um eventuelle Umwelt oder Gesundheitssch den durch unkontrollierte Abfallbe...

Page 14: ...ze Anleitung Wasserdichtes RJ45 Zubeh r Kabelverbindungsblock Kieselgel i Hinweis Pr fen Sie den Packungsinhalt um sicherzustellen dass Sie das vollst ndige System mit allen oben genannten Komponenten...

Page 15: ...t 2 Stromanschluss_ROT DC12V IN Dient zum Anschluss an ein Gleichstromkabel 3 Alarmeingang Alarm Eingang Signal anschlie en 4 Alarm Ausgang Alarmausgangssignal anschlie en 5 Netzwerk Anschluss an den...

Page 16: ...ID und Ihr Passwort ein um sich anzumelden Sie k nnen den berwachungsbildschirm nach der Anmeldung sehen i Hinweis Sie m ssen Ihr Login Passwort registrieren wenn Sie sich zum ersten Mal anmelden Wie...

Page 17: ...wird die Kamera nach einer gewissen Zeit auf eine Standard IP Adresse zur ckgesetzt In diesem Fall f gen Sie mehrere Kameras bit te nur nacheinander zum Netzwerk hinzu um Konflikte aufgrund der ident...

Page 18: ...ie Kamera 9 Momentaufnahme Speichert das aktuelle Bild als jpg Datei 10 Drucken Druckt den aktuellen Bildschirm 11 Notfall Aufnahme Notfall Aufnahme starten 12 Alarm Wird aktiviert wenn ein Ereignis e...

Page 19: ...en Lizenzbe dingungen finden Sie in der Benutzeroberfl che Ihrer Produkte enthaltenen Open Source Informationen auf den Produktdetailseiten auf der eneo Website www eneo security com im eneo Downloadp...

Page 20: ...ribution through specialised trade channels only VIDEOR E Hartig GmbH Carl Zeiss Stra e 8 63322 R dermark Germany Tel 49 0 6074 888 0 Fax 49 0 6074 888 100 www videor com www eneo security com Technic...

Reviews: