7
Installation instructions
Cover Opening Alarm and External Alarm Input
CAUTION: Cover Opening(Sabotage) Alarm and External Alarm
Input are electrically tied together internally. Alarm contact types,
N.O or N.C are selectable by the Alarm Input Selection Jumper
and the selection types should be matched with Alarm Type in
setup menu.
When both of Cover Opening Alarm and External Alarm Input
are used at the same time, the alarm contact types must match.
Otherwise, alarm malfunctions. When External Alarm Input only
is used with disabling Cover Opening Alarm, remove the jumper
cap of Alarm Input Selection Jumper.
For Cover Opening Alarm, please go to SETUP> Event Rules> Event Processing>
Add Event Trigger should be set to “Alarm In” and then Event Action should be
set as available options.
Using Grommet
wrap the cable properly as illustrated. If it doesn’t wrap the cable properly,it could cause
the water leakage problem.
Cover opening alarm switch
(Sabotage alarm)
Alarm Input selection jumper