ENC CHIMNEY
SYSTEM
3
INSTALLATION ONTO A CHIMNEY
1. Remove any existing connector pipe
installed between the appliance and the
Support Box connection.
2. Visually inspect with a flashlight the
condition of the interior of the chimney
for cleanliness and structural integrity. All
evidence of soot and creosote must be
removed from the existing chimney system.
If you doubt your ability to accomplish this,
contact a certified chimney sweep. Do not
use chemical cleaners, as these can possibly
damage the inside of the chimney. Do
any required maintenance on the existing
chimney system at this time.
3. Connect and seal the appropriate size
EPV Chimney Adapter to the ENC Chimney
Support Box with high temperature RTV
silicone sealant. Secure the connection with
three sheet metal screws.
4. Connect the appliance to the Chimney
Adapter using an Appliance Adapter, lengths
of pipe as required, and an Adjustable Length
pipe. Slide the Adjustable Length down over
the top pipe section, position the installation
vertically plumb, then slip the Adjustable
Length up and twist lock it to the Chimney
Adapter. Once all the components are firmly
seated and properly aligned, carefully drill
three 1/8” diameter holes through the outer
sleeve only in the center of the slots located
at the bottom of the Adjustable Length
pipe. Do not penetrate the inner liner. Use
(3) 3/8” length sheet metal screws to secure
the Adjustable Length pipe. The completed
installation will look like Figure 1.
EPV
CHIMNEY
ADAPTER
CHIMNEY
SUPPORT BOX
EPV
CHIMNEY
ADAPTER
EPV SYSTEM
Figure 1