ENC CHIMNEY 

SYSTEM

3

INSTALLATION ONTO A CHIMNEY

1. Remove any existing connector pipe 
installed between the appliance and the 
Support Box connection. 

2. Visually inspect with a flashlight the 
condition of the interior of the chimney 
for cleanliness and structural integrity. All 
evidence of soot and creosote must be 
removed from the existing chimney system. 
If you doubt your ability to accomplish this, 
contact a certified chimney sweep. Do not 
use chemical cleaners, as these can possibly 
damage the inside of the chimney. Do 
any required maintenance on the existing 
chimney system at this time.

3. Connect and seal the appropriate size 
EPV Chimney Adapter to the ENC Chimney 
Support Box with high temperature RTV 
silicone sealant. Secure the connection with 
three sheet metal screws.

4. Connect the appliance to the Chimney 
Adapter using an Appliance Adapter, lengths 
of pipe as required, and an Adjustable Length 
pipe. Slide the Adjustable Length down over 
the top pipe section, position the installation 
vertically plumb, then slip the Adjustable 
Length up and twist lock it to the Chimney 
Adapter. Once all the components are firmly 
seated and properly aligned,  carefully drill 
three 1/8” diameter holes through the outer 
sleeve only in the center of the slots located 
at the bottom of the Adjustable Length 
pipe. Do not penetrate the inner liner. Use 
(3) 3/8” length sheet metal screws to secure 
the Adjustable Length pipe. The completed 
installation will look like Figure 1.

EPV

CHIMNEY

ADAPTER

CHIMNEY

SUPPORT BOX

EPV

CHIMNEY

ADAPTER

EPV SYSTEM

Figure 1