8
4. When a battery is placed in the charging pod and while charging, the charge status
LED (F or R) will illuminate RED with no flashing. If the charge status LED is red and
flashes, a fault has been detected. The flash pattern represents a specific fault condi-
tion. See section
Fault Conditions
for details.
5. When the battery is charged to 80% of capacity, the charge status LED will change to
GREEN and begin to flash. It is recommended that the battery be charged to at least
80% capacity before use.
6. The charge status LED will illuminate GREEN with no flashing when the battery is fully
charged.
7. After removing a fully charged battery, the charge status LED will illuminate ORANGE
for a few seconds. Allow the charge status LED to go off before placing another bat-
tery in the charging pod.
8. The TWC12M is designed to operate at room temperatures between 15°C and 30°C
(59° F – 86° F). Do not charge batteries at temperatures below 0°C (32° F) or above
45°C (113° F).
Charging A Battery
(continued)