4. CHECK OPERATION OF ENTRY SET
A. Verify lock and handle operation with the door open.
• Rotate thumbturn 90°. Latch bolts should extend to deadbolted position. Rotate 90° the other direction. The
latch bolts should retract to original position.
• Rotate thumbturn 90° again. Latch bolts should extend to deadbolted position.
• Press on the end of each latch bolt individually to ensure they do not collapse. If they do, the door is not fully
deadbolted. Check the fabrication to see where the interference is.
• Operate exterior grip trigger. The latch bolts should remain in deadbolted position.
• Operate interior lever downward. The latch bolts should fully retract.
• Operate exterior grip lever. The latch bolts should fully retract.