Replacing A Charging Pod

The charging pod is made from quality materials and designed to provide 

years of service when properly used. In most cases, the charging pod will 

only be replaced when you want to use the charger with a different battery.

Follow these steps to change the charging pod:

Obtain a charging pod made specifically for the ENDURA™ NCC0325. 

Confirm 

that the charging pod is compatible with the battery you want to charge.
Unplug the AC to DC power supply from the ENDURA™ NCC0325.
Turn the locking screw on the bottom of the charging pod counter-clock-

wise several rotations.  (The screw remains connected to the charging 

pod.)  Lift the charging pod from the charging base.
Insert the replacement charging pod into the charging base and secure 

with the locking screw.  Do not over tighten the screw.
Inspect the charging contacts to ensure they are clean and unobstructed.
Connect the AC to DC power supply to the ENDURA™ NCC0325. You are

now ready to charge a battery compatible with the charging pod.

1.

2.
3.

4.

5.
6.

Summary of Contents for NCC0325

Page 1: ...Model NCC0325 FOR RECHARGEABLE LMR BATTERIES Single Unit Rapid Charger...

Page 2: ...charge a battery Check to make sure a charging pod compatible with your battery is prop erly installed on charger before placing battery in pod Position charger away from TVs radios or other receiver...

Page 3: ...or removing the charging pod Make sure contacts in charging pod and battery are clean Do not allow wire or metal objects to touch contacts in charging pod or any internal part of the charger Do not re...

Page 4: ...e battery you want to charge Unplug the AC to DC power supply from the ENDURA NCC0325 Turn the locking screw on the bottom of the charging pod counter clock wise several rotations The screw remains co...

Page 5: ...ashing If the charge status LED is red and flashes a fault has been detected The flash pattern represents a specific fault condition See section Fault Conditionsfor details When the battery is charged...

Page 6: ...ry diagnostic has timed out and cannot be completed due to excessively low battery voltage Charge battery with charger supplier with radio then resume use of ENDURA NCC0325 Flashes 3 Times Indicates o...

Page 7: ...related entities or their respective directors officers or employees be liable for any damages beyond repair or replacement as described above including without limitation indirect incidental or con s...

Page 8: ...istries NiCd NiMH Li Ion Operating Temperature 15 C 30 C Storage Temperature 0 C 65 C Power Supply Type AC to DC Power Supply Output 15V 18V DC 500mA 900mA Specifications subject to change without not...

Reviews: