20
www.uniquip.ca
Maintenance Procedures cont’d ...
5.Replacing the Rotor Assembly (ENAR24HC-42) and Bearing Assemblies (ENAR24HC-38)
i. Follow steps 1-4 in “Changing the Drive Chain”.
ii. Unbolt bearing assemblies from both ends of the rotor (see fi g.15).
iii. Remove rotor assembly (see fi g.16).
iv. Inspect bearing assemblies (ENAR24HC-38) and sprocket (ENAR24HC-39) for any wear.
Replace if necessary.
v. Reverse these steps to re-install the rotor.
vi. Follow steps 5-7 to reinstall drive chain.
vii. After re-installing the chain, verify that the drive chain tension is set appropriately.
See “Adjusting the Drive Chain” for instructions.
Fig.12:
Correctly installed drive belt
Fig.13:
Incorrectly installed drive belt
Fig.14:
Adjusting belt tension on
clutch cable
Fig.15:
Rotor will drop when bearing
assemblies are removed
Fig.16:
Completely remove rotor and
set aside with drive chain and
other components for re-installation