Specifications (EC6M / EC6M-V2)

Specifications subject to change without notice.

Dimensions (W x L x H) 
Weight 
Compatible Chemistries
Ambient Operating Temperature 
Power Supply 

(TWC6M-PS)

Charger Input 

A

 

Charge Rate 

B

 

Approvals 

509 x 148 x 91 mm / 20.0 x 5.8 x 3.6 inches
1.4 kg / 3.1 lbs. 

(charger only)

Li-Ion / LiPo / NiMH / NiCd 

(based on pod selected)

5° C - 40° C / 41° F - 104° F
100V – 240V AC / 50 Hz – 60 Hz / 2.0A
12V-24V DC / 5.4A

 (minimum)

900 mA (10.6V-13.5V)
FCC

C

 / BC

D

 / DOE

/

 

CE

(A) Applies to EC6M. Charger input for EC6M-V2 is 4.8A (minimum). (B) Applies to EC6M. Charge rate for 

EC6M-V2 is 700 mA. (C) Complies with FCC Rules, Part 15, Subpart B, Class B 2016, ANSI C63.4:2014. (D) 

Complies with CaliforniaEnergy Commission CEC-400-2011-005. (E) Complies with U.S. Department of Energy 

10 CFR, Part 430, PC3 and 4. This device complies with Part 15 of the FCC Rules. Operation is subject to the 

following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept 

any interferencereceived, including interference that may cause undesired operation.

Summary of Contents for EC6M

Page 1: ...User Manual Models EC6M EC6M V2 FOR RECHARGEABLE TWO WAY RADIO BATTERIES Six Unit Rapid Charger...

Page 2: ......

Page 3: ...duction Important read before use Caution read before use EC6M Features Accessories For In Vehicle Use Replacing A Charging Pod Charging A Battery Fault Conditions Advisements Warranty And Service Spe...

Page 4: ...atible with nearly all Endura TWP charging pods and for those pods that are not compatible the model EC6M V2 is available Feature differences for EC6M V2 are noted in this manual where appropriate The...

Page 5: ...Read all Caution statements below and this User Manual before attempting to charge a battery 2 Check to make sure a charging pod compatible with your battery is properly installed before charging a ba...

Page 6: ...e overcharge protection 2 Use charger in areas protected from the weather Do not expose the charger to rain any liquids or excessive moisture 3 Do not attempt to charge a battery without first install...

Page 7: ...other power supplies or DC power accessories may damage the charger or batteries you may be attempting to charge C AUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOC...

Page 8: ...ction port for AC to DC power supply or TWC6M VPA 3 Removable charging pod shown for one position only 4 DC power connection port 5 Charge status LED shown for one position only 6 Status LED informati...

Page 9: ...6 10 8 9 EC6M Features continued 8 AC to DC power supply TWC6M PS 9 DC power plug connects to charger 10 Power cord to connect power supply to AC outlet...

Page 10: ...For In Vehicle Use The items below are available for EC6M and allow the charger to be used in a vehicle 1 Mounting bracket with integrated tie down straps and fasteners EC6M MB 2 Vehicle power adapter...

Page 11: ...8 Accessories For In Vehicle Installation continued 3 4 3 Hardwire kit TWC6M HW 4 Vibration tolerant DC power connection port for TWC6M HW...

Page 12: ...want to charge 2 Unplug the charger from its power source 3 The charging pod is secured to the base with a single screw To remove turn the locking screw on the bottom of the charging pod counter clock...

Page 13: ...ashing to indicate normal charging 5 If the status LED is red and flashes a fault has been detected The flash pattern represents a specific fault condition If the status LED is orange solid or flashin...

Page 14: ...3 F batteries outside this temperature will not be charged EC6M V2 is designed to charge batteries without a temperature monitoring circuit or with a temperature monitoring circuit that is not compati...

Page 15: ...e battery is defective and should be recycled This warning is provided after the pre charge stage is completed LED Pattern Fault Description EC6M EC6M V2 When the charge status LED flashes RED a fault...

Page 16: ...gh the and contacts on the battery This warning is provided after the initial diagnostic stage is complete Check charging pod to confirm compatibility with battery Battery temperature is 45 C 113 F or...

Page 17: ...above freezing Monitoring terminates if the battery temperature remains below freezing for two hours Remove battery and reinsert once battery reaches room temperature If B battery type requires additi...

Page 18: ...r charged Battery voltage is below minimum level required This warning is provided after the rapid charging stage is complete LED Pattern Advisement EC6M EC6M V2 Flashes ORANGE 1 Time Battery temperat...

Page 19: ...duct has been altered misused damaged neglected or if repair is required because of normal wear and tear This is the only warranty made by PPU In no event will PPU its affiliates subsidiaries related...

Page 20: ...0004 For your protection we recommend you obtain proof of delivery for your shipment Include with your product dated proof of purchase your name and daytime telephone number and return address street...

Page 21: ...0 mA 10 6V 13 5V FCCC BCD DOEE CE A Applies to EC6M Charger input for EC6M V2 is 4 8A minimum B Applies to EC6M Charge rate for EC6M V2 is 700 mA C Complies with FCC Rules Part 15 Subpart B Class B 20...

Page 22: ...TWC6M VPA Heavy duty vehicle power adapter Length 24 0 cord relaxed Replaceable fuse 6A TWC6M HW Hardwire kit for in vehicle installation Length 13 0 Components and cable rated to 15A EC6M MB Mounting...

Page 23: ......

Page 24: ...rt Adaptable Reliable 2170 Brandon Trail Alpharetta GA 30004 www powerproducts com 2017 Power Products Unlimited Inc Power Products Endura and Smart Adaptable Reliable are trademarks of Power Products...

Reviews: