18
Specifications (EC6M / EC6M-V2)
Specifications subject to change without notice.
Dimensions (W x L x H)
Weight
Compatible Chemistries
Ambient Operating Temperature
Power Supply
(TWC6M-PS)
Charger Input
A
Charge Rate
B
Approvals
509 x 148 x 91 mm / 20.0 x 5.8 x 3.6 inches
1.4 kg / 3.1 lbs.
(charger only)
Li-Ion / LiPo / NiMH / NiCd
(based on pod selected)
5° C - 40° C / 41° F - 104° F
100V – 240V AC / 50 Hz – 60 Hz / 2.0A
12V-24V DC / 5.4A
(minimum)
900 mA (10.6V-13.5V)
FCC
C
/ BC
D
/ DOE
E
/
CE
(A) Applies to EC6M. Charger input for EC6M-V2 is 4.8A (minimum). (B) Applies to EC6M. Charge rate for
EC6M-V2 is 700 mA. (C) Complies with FCC Rules, Part 15, Subpart B, Class B 2016, ANSI C63.4:2014. (D)
Complies with CaliforniaEnergy Commission CEC-400-2011-005. (E) Complies with U.S. Department of Energy
10 CFR, Part 430, PC3 and 4. This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interferencereceived, including interference that may cause undesired operation.