9
5. If the charge status LED is RED and flashes, a fault has been detected. The flash pat-
tern represents a specific fault condition. If the status LED is ORANGE (solid or flash-
ing), an advisement is being provided. See section
Fault Conditions & Advisements
.
6. When the battery is charged to 80% of capacity, the charge status LED will change to
GREEN and begin to flash. It is recommended that the battery be charged to at least
80% capacity before use.
7. The charge status LED will illuminate GREEN with no flashing when the battery is fully
charged.
8. After removing a fully charged battery, the charge status LED will illuminate ORANGE
for a few seconds. Allow the charge status LED to go off before placing another
battery in the charging pod.
9. EC2M is designed to charge batteries with a temperature monitoring circuit when
the battery temperature is between 0°C and 45°C (32° F – 113° F); batteries outside
this temperature will not be charged. The ambient temperature should be 5°C - 40°C
(41° F - 104° F) while charging a battery.