Power supply

Electrical connection

Screw terminals on electronic insert for max. 2.5 mm

2

 wire in end sleeve A 2.5 - 7 to DIN 46 228

L00-FTM260xx-04-05-xx-xx-002

Electronic insert FEM31

Two-wire AC connection (thyristor)

!

Note! 
Always connect in series with the load!

Check the following:

• the residual current in blocked state (up to 3.8 mA)
• that for low voltage

– the voltage drop across the load such so that the minimum terminal voltage at the electronic insert (19 V) 

 when blocked is not too low.

– the voltage drop across the electronic insert when open is observed (up to 12 V).

• that a relay cannot de-energise with a retaining current below 3.8 mA.

If this is the case, a resistor should be connected parallel to the relay.

Electronic insert FEM32 

Three-wire DC connection (transistor,

 PNP)

Designed to be connected to programmable logic controllers (PLC).
Positive signal at switching output of the electronic insert (PNP).

Electronic insert FEM34 

Universal connection (relay, potential-free changeover contact)

Potential-free changeover contact.

Supply voltage

• Output  with  FEM31

Voltage at Terminals 1 and 2: 19...253 V, 50/60 Hz,
Current consumption (stand-by) max. 3.8 mA

• Output  with  FEM32

10...55 V, ripple max. 1.7 V, 0...400 Hz, 
Current consumption max. 15 mA, protection against reverse polarity

• Output  with  FEM34

AC 19...253 V, 16...60 Hz or DC 19...200 V,
Current consumption max. 7 mA

1

2

L1 N

19...253 V

1 A

U~

1

2

3 (+)

L+ L–

a u r

L1 N

1

2

3 4 5

U– 10...55 V

U~ 19...253 V

U– 19...200 V

0.5 A

0.2 A

FEM 31

FEM 32

FEM 34

Summary of Contents for Soliphant T FTM260

Page 1: ...esign and constructional materials also make it suitable for foodstuff applications Examples grain flour milk powder cocoa sugar animal feed washing powders dyes chalk plaster cement plastic granulate...

Page 2: ...t 7 Ambient temperature 7 Storage temperature 7 Climate class 7 Degree of protection 7 Mechanical load on fork 7 Electromagnetic compatibility 7 Process 7 Medium temperature 7 Temperature diagram 7 Bu...

Page 3: ...e vessel walls Soliphant FTM260 can be operated in both minimum or maximum fail safe mode i e the electronic switch opens or the relay de energises on reaching the limit value on a fault or on a loss...

Page 4: ...escent current max 3 8 mA with open thyristor with FEM32 The load is switched via a transistor and separate PNP connection Short term 1 s max 1 A max 55 V cyclic overload and short circuit protection...

Page 5: ...current below 3 8 mA If this is the case a resistor should be connected parallel to the relay Electronic insert FEM32 Three wire DC connection transistor PNP Designed to be connected to programmable...

Page 6: ...with roof length approx 250 mm width approx 200 mm to protect against collapsing mounds d in discharge hopper Right incorrect e in filling curtain f false orientation of the fork high load on the wide...

Page 7: ...to EN 61326 Electrical Equipment Class B Interference Immunity to EN 61326 Annex A Industrial and NAMUR Recommendation NE 21 EMC Process Medium temperature 40 C 150 C 40 F 300 F see also Temperature d...

Page 8: ...ered in stainless steel 1 NPT tapered d Vibrating fork in solid stainless steel with high mechanical resistance to lateral loads Weight approx 1 1 kg with electronic insert Material Process connection...

Page 9: ...safe mode is selected by turning a switch Max Min FEM E F 20 Process Connection G Thread DIN2999 R1 304 N Thread ANSI NPT1 304 Y Special version 30 Electronics Output Y Special version 1 FEM31 2 wire...

Page 10: ...Soliphant T FTM260 10 Endress Hauser...

Page 11: ...Soliphant T FTM260 Endress Hauser 11...

Page 12: ...Head Quarter Endress Hauser GmbH Co KG Instruments International Colmarer Str 6 79576 Weil am Rhein Deutschland Tel 49 76 21 9 75 02 Fax 49 76 21 9 75 34 5 www endress com info ii endress com TI238F 0...

Reviews: