RID16
Trouble-shooting
Hauser
31
9.2
Status messages
The device displays warnings or alarms as status messages. If errors occur during commissioning,
these errors are displayed immediately. This takes place in the configuration program by means of
the parameter in the Adv. Diagnostic Block or on the mounted display. A distinction is made here
between the following 4 status categories:
WARNING or ALARM error category:
The display alternates between the displayed values and the error message (= letter in question plus
the defined error number, e.g. "F283").
In case that more than one value is displayed the display alternates between the values and the error
message in the following way:
• e.g. channel 1, channel 2 and channel 3 are configured to display a value
• value of channel 1 => error message => value of channel 2 => error message => value of channel
3 => error message => value of channel 1 => ...
In the case that no value is to be displayed and an error occurs, the display alternates between "- -
- - -" and the error message.
!
Note!
1.
As long as the error message is active the alternating time is set to 2 seconds. After the error
has been removed the alternating time will return to its normal value written into the
Parameter "DISP_ALTERNATING_TIME"
2.
If the ALARM "F437" is generated by a channel the value of that channel will be replaced on
the display by "- - - - -"
Transducer Blocks:
The manufacturer-specific
parameters are not visible.
The device description file (Device Description, DD) has not yet been loaded to the
host system or the configuration program?
→
Download the file to the configuration
system.
For information on where to obtain the DD,
!
Note!
Make sure you are using the correct system files for integrating field devices into the
host system. Relevant version information can be queried with the device by means
of the following functions/parameters:
FF interface:
• Resource Block
→
DD_REV parameter
Example:
Display in DEV_REV parameter
→
01
Display in the DD_REV parameter
→
01 (the smallest possible DD revision)
Device description file (DD) required
→
0101.sym / 0101.ffo
!
Hinweis!
Please always use the latest DD revision.
Æ
Other errors (application errors without messages)
Some other error has occurred.
Possible causes and remedial measures
Status category
Description
Error category
F
Fault detected ('Failure')
ALARM
M
Maintenance necessary
WARNING
C
Device is in the service mode (check)
S
Specifications not observed ('Out of
specification')