10.3 Gauge commands
10.3.1 Overview of available device functions
Gauge commands are mainly divided into two categories.
• Continuous gauge command
• One-time gauge command (non-continuous)
One-time gauge commands have a defined end state. After a one-time gauge
command is completed, another gauge command is executed which is defined by the
Post gauge command
parameter. If
Post gauge command
is set to
None
, the
operation will stop.
The gauge command can be chosen by navigating to Operation → Gauge command. The
status of the gauge command execution is shown in the
Gauge status
parameter. The
gauge status is displayed on the home screen by default.
X X X X
X X X
X
X
5
2
1
3
mm
4841.00
Level bal.
F
4
A0028702
53
Typical appearance of the standard view (measured value display)
1
Display module
2
Device tag
3
Status area
4
Display area for measured values
5
Display area for status symbols
For details of status symbols → 52
When a one-time gauge command is executed, additional information is shown in the
One-time command status
parameter in the operation menu.
10.3.2 Descriptions of gauge commands
The following table shows the available gauge commands and functions of NMS8x.
The numbers in the figures show the sequence of displacer movement.
Gauge
command
Descriptions
Post gauge
command
Stop
Displacer stops.
Not available
Level
The displacer searches for the liquid level
surface and balances there.
Not available