Safety Instructions

Documentation for hazardous location Cl.I Div.1

XA00113D/06/EN/13.10
71127791

Proline Prosonic Flow 92F

HART, PROFIBUS PA, FOUNDATION Fieldbus
XP (Ex-d version)

Division 1

2

Safety instructions for electrical apparatus for explosion-hazardous areas according to 
FACTORY MUTUAL standards 

Page 3

1

Safety instructions for electrical apparatus for explosion-hazardous areas according to 
CANADIAN STANDARDS ASSOCIATION 

Page 9

Summary of Contents for Proline Prosonic Flow 92F

Page 1: ...92F HART PROFIBUS PA FOUNDATION Fieldbus XP Ex d version Division 1 2 Safety instructions for electrical apparatus for explosion hazardous areas according to FACTORY MUTUAL standards Page 3 1 Safety...

Page 2: ...III Group Gases vapours and dust examples Gas Dust Fibre CSC NEC Min ignition temperature J m A B C D E F G 0 02 0 02 0 06 0 18 Acetylene c Class I Class I Class I Class I Metallic powder Class II Cl...

Page 3: ...PA BA128D Proline Prosonic Flow 92F FOUNDATION Fieldbus Table of Contents FM General warnings 4 Special conditions 4 Installation instructions 4 Approvals 4 Description of the measuring system 4 Devi...

Page 4: ...asuring system must be included in potential matching see Page 7 The devices may only be used for fluids against which the wetted materials are sufficiently resistant The service connector may not be...

Page 5: ...SEALED Provides intrinsically safe sensor circuits See control drawings 1 5W 4153 Reinach Switzerland 2006 1 2 3 4 6 5 A 7 5P CAL TM 40 C 40 F 150 C 302 F CF3M 1 4404 F316L Materials DN100 4 DIN EN PN...

Page 6: ...to 383 40 to 392 40 to 392 40 to 140 40 to 266 40 to 383 40 to 392 40 to 392 Prosonic 92F P H K 40 to 140 40 to 266 40 to 383 40 to 392 40 to 392 Ta Tmed F T6 185 F T5 212 F T4 275 F T3 392 F T2 572...

Page 7: ...ess Hauser max 98 ft 30 m complies with these values Electrical connections Terminal electronics compartment cover terminal assignment see tables below e Service connector see also Page 8 f HART groun...

Page 8: ...sensor correspond to the standard versions Please refer to the Technical Information for these dimensions Note Associated Technical Information Proline Prosonic Flow 92F TI073D 06 Control drawings En...

Page 9: ...D Proline Prosonic Flow 92F FOUNDATION Fieldbus Table of Contents CSA General warnings 10 Special conditions 10 Installation instructions 10 Approvals 10 Description of the measuring system 10 Device...

Page 10: ...must be included in potential matching see Page 13 The devices may only be used for fluids against which the wetted materials are sufficiently resistant The service connector may not be connected in...

Page 11: ...SEALED Provides intrinsically safe sensor circuits See control drawings 1 5W 4153 Reinach Switzerland 2006 1 2 3 4 6 5 A 7 5P CAL TM 40 C 40 F 150 C 302 F CF3M 1 4404 F316L Materials DN100 4 DIN EN PN...

Page 12: ...40 to 130 40 to 195 40 to 200 40 to 200 40 to 60 40 to 130 40 to 195 40 to 200 40 to 200 Prosonic 92F P H K 40 to 60 40 to 130 40 to 195 40 to 200 40 to 200 Ta Tmed C T6 85 C T5 95 C T4 135 C T3 200 C...

Page 13: ...ndress Hauser max 30 m complies with these values Electrical connections Terminal electronics compartment cover terminal assignment see tables below e Service connector see also Page 14 f HART ground...

Page 14: ...ensor correspond to the standard versions Please refer to the Technical Information for these dimensions Note Associated Technical Information Proline Prosonic Flow 92F TI073D 06 Control drawings Endr...

Page 15: ...Proline Prosonic Flow 92F 1 Endress Hauser 15...

Page 16: ...www endress com worldwide XA00113D 06 EN 13 10 71127791 FM SGML 6 0...