Proline Promass Q 300
Hauser
19
Intrinsically safe values Intrinsically safe values Intrinsically safe or NIFW values
Order code for
"Output; input 1"
Output type
Intrinsically safe values
"Output; input 1"
26 (+)
27 (–)
Option
CA
Current output 4-20 mA
HART Ex i
U
i
= 30 V
l
i
= 100 mA
P
i
= 1.25 W
L
i
= 0
C
i
= 0
Option
HA
PROFIBUS PA Ex i
Ex ia
U
i
= 30 V
l
i
= 570 mA
P
i
= 8.5 W
L
i
= 10 µH
C
i
= 5 nF
Ex ic
U
i
= 32 V
l
i
= 570 mA
P
i
= 8.5 W
L
i
= 10 µH
C
i
= 5 nF
Option
TA
FOUNDATION Fieldbus
Ex i
Ex ia
U
i
= 30 V
l
i
= 570 mA
P
i
= 8.5 W
L
i
= 10 µH
C
i
= 5 nF
Ex ic
U
i
= 32 V
l
i
= 570 mA
P
i
= 8.5 W
L
i
= 10 µH
C
i
= 5 nF
1)
Only available for the Zone 1, Class I, Division 1 version
2)
Only available for the Zone 2, Class I, Division 2 version transmitter
Order code for
"Output; input 2";
"Output; input 3"
Output type
Intrinsically safe values Intrinsically safe values
Intrinsically safe or NIFW values
Output; input 2
Output; input 3
24 (+)
25 (–)
22 (+)
23 (–)
Option
C
Current output 4-20 mA
Ex i
U
i
= 30 V
l
i
= 100 mA
P
i
= 1.25 W
L
i
= 0
C
i
= 0
Option
G
Pulse/frequency/switch
output Ex i
U
i
= 30 V
l
i
= 100 mA
P
i
= 1.25 W
L
i
= 0
C
i
= 0
Low flow cut off
The switch points for low flow cut off are user-selectable.
Galvanic isolation
The outputs are galvanically isolated from one another and from earth (PE).
Protocol-specific data
HART
Manufacturer ID
0x11
Device type ID
0x3B
HART protocol revision
7
Device description files
(DTM, DD
)
Information and files under:
HART load
Min. 250 Ω