Proline Promag W 400 HART
Installation
Hauser
25
200
100
5
10
100
200
[m]
[ S/cm]
µ
L max
[ ]
ft
200
600
0
400
L max
A0016539
9
Permitted length of connecting cable for remote version
Colored area
=
permitted range
L
max
=
length of connecting cable in [m] ([ft])
[µS/cm]
=
fluid conductivity
6.1.3
Special mounting instructions
Display protection
‣
To ensure that the optional display protection can be easily opened, maintain the
following minimum head clearance: 350 mm (13.8 in)
Permanent immersion in water
A fully welded remote version with IP68 protection is optionally available for permanent
immersion in water ≤ 3 m (10 ft) or in exceptional cases for use for up to 48 hours at ≤
10 m (30 ft). The measuring device meets the requirements of corrosion categories C5-M
and Im1/Im2/Im3. The fully welded design along with the connection compartment
sealing system ensure that moisture cannot enter the measuring device.
≤
≤
3 (
10)
A0029320
10
Engineering unit in m(ft)
Replacement of cable gland on connection housing → 155
Buried applications
A remote version with IP68 protection is optionally available for buried applications. The
measuring device satisfies the certified corrosion protection Im1/Im2/Im3 in accordance
with EN ISO 12944. It can be used directly underground without the need for additional
Summary of Contents for Proline Promag W 400 HART
Page 197: ......