Proline Promag 55S
18
Hauser
Length of connecting cable
In order to ensure measuring accuracy, comply with the following instructions when installing the remote
version:
• Secure the cable run or route the cable in an armored conduit. Movement of the cable can falsify the meas-
uring signal, particularly if the fluid conductivity is low.
• Route the cable well clear of electrical machines and switching elements.
• Ensure potential equalization between sensor and transmitter, if necessary.
• The permissible cable length L
max
depends on the fluid conductivity (see Figure).
A0006116
Permitted lengths for connecting cable in remote version, as a function of the conductivity of the fluid
Gray shaded area = permissible area
L
max
= Length of connecting cable
[μS/cm]
50
40
30
20
10
5
0
10
0
20
30
40
50
[m]
L
max
L
max
50
100
150
0
[ft]