Wiring
Promag 50
46
Hauser
Promag H
A0011747
Fig. 32:
Connecting the remote version of Promag H
a
Wall-mount housing connection compartment
b
Cover of the sensor connection housing
c
Signal cable
d
Coil current cable
n.c.
Not connected, insulated cable shields
Wire colors/Terminal No.:
5/6 = braun, 7/8 = white, 4 = green, 37/36 = yellow
E1
E2
GND
E
S1
E1
E2
S2
GND
E
S
5
7
4 37
42 41
42 41
6
5
7
8
4 37 36
n.c.
n.c.
d
c
c
d
a
b
n.c.