Endress+Hauser iTEMP TMT82 Brief Operating Instructions Download Page 7

iTEMP TMT82

Incoming acceptance and product identification

Hauser

7

3.

DELIVERY NOTE

  A0037102

Does the nameplate match the ordering information on the delivery note?

4.

TMT72

  A0024858

Are the technical documentation and all other necessary documents provided? If

applicable: are the Safety Instructions (e.g. XA) for hazardous areas provided?

If one of these conditions is not satisfied, contact your Hauser Sales Center.

3.2  

Product identification

The following options are available for identification of the device:

• Nameplate specifications

• Extended order code with breakdown of the device features on the delivery note

• Enter the serial number from the nameplate in the 

W@M Device Viewer

(

www.endress.com/deviceviewer

): All data relating to the device and an overview of the

Technical Documentation supplied with the device are displayed.

• Enter the serial number on the nameplate into the 

Hauser Operations App

 or scan

the 2-D matrix code (QR code) on the nameplate with the 

Hauser Operations App

:

all the information about the device and the technical documentation pertaining to the

device is displayed.

3.2.1  

Nameplate

The right device?

Compare and check the data on the nameplate of the device against the requirements of the

measuring point:

Summary of Contents for iTEMP TMT82

Page 1: ...ctions they do not replace the Operating Instructions included in the scope of supply Detailed information can be found in the Operating Instructions and the additional documentation Available for all...

Page 2: ...iTEMP TMT82 2 Endress Hauser Order code Ext ord cd Ser no www endress com deviceviewer Endress Hauser Operations App XXXXXXXXXXXX XXXXX XXXXXX XXX XXXX XX Serial number 1 3 2 A0023555...

Page 3: ...ng requirements 10 4 2 Mounting 11 4 3 Post mounting check 15 5 Electrical connection 16 5 1 Connection conditions 16 5 2 Quick wiring guide 16 5 3 Connecting the sensor cables 17 5 4 Connecting the t...

Page 4: ...ctional safety Please refer to Safety Manual SD01172T 09 for the use of approved devices in protective systems according to IEC 61508 1 2 Symbols 1 2 1 Safety symbols Symbol Meaning DANGER A0011189 EN...

Page 5: ...Trained qualified specialists must have a relevant qualification for this specific function and task Are authorized by the plant owner operator Are familiar with federal national regulations Before be...

Page 6: ...device is used in the hazardous area e g explosion protection or safety equipment Based on the technical data on the nameplate check whether the ordered device is permitted for the intended use in the...

Page 7: ...te specifications Extended order code with breakdown of the device features on the delivery note Enter the serial number from the nameplate in the W M Device Viewer www endress com deviceviewer All da...

Page 8: ...symbols 7 Order code and manufacturer ID 6 0044 iTEMP TMT82 Made in Germany 2012 D 87484 Nesselwang TAGXXXXXXXXXXX TAGXXXXXXXXXXX Order code TMT82 xxx xx Ext ord cd XXXXXXXXXXX Ser no XXXXXXXXX Input...

Page 9: ...requirements of the standards EN 61 010 1 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use and with the EMC requirements as per the IEC EN 61326 series 3 4 1 CE...

Page 10: ...ls Dimensions in mm in A Spring travel L 5 mm not for US M4 securing screws B Mounting elements for attachable measured value display C Interface for contacting measured value display The same dimensi...

Page 11: ...tion option JN 1 SIL Mode 40 to 70 C 40 to 158 F Head transmitter in accordance with climate class C1 DIN rail transmitter in accordance with B2 as per EN 60654 1 Condensation as per IEC 60068 2 33 pe...

Page 12: ...l head cover 8 on the terminal head 2 Guide the connection wires 4 of the insert 3 through the center hole in the head transmitter 5 3 Fit the mounting springs 6 on the mounting screws 7 4 Guide the m...

Page 13: ...ws 2 through the lateral bores in the head transmitter 3 3 Screw the head transmitter to the field housing 4 After wiring close the field housing cover 1 again 16 Procedure for mounting on a DIN rail...

Page 14: ...ting screws 6 through the lateral bores of the head transmitter 5 5 Position the head transmitter 5 in the terminal head 4 in such a way that the bus cable terminals 1 and 2 point to the cable entry 6...

Page 15: ...top A0017821 8 Mounting the DIN rail transmitter 1 Slide the upper DIN rail clip upwards and the lower clip downwards until they click into place 2 Fit the device on the DIN rail from the front 3 Slid...

Page 16: ...ead transmitter 1 Open the cable gland and the housing cover on the terminal head or the field housing 2 Feed the cables through the opening in the cable gland 3 Connect the cables as shown in 16 If t...

Page 17: ...ult in the destruction or malfunction of parts of the electronics 5 3 Connecting the sensor cables NOTICE When connecting 2 sensors ensure that there is no galvanic connection between the sensors e g...

Page 18: ...Fig A solid wire 1 Strip wire end Min stripping length 10 mm 0 39 in 2 Insert the wire end into the terminal 3 Pull the wire gently to ensure it is connected correctly Repeat from step 1 if necessary...

Page 19: ...er Cable specification A normal device cable suffices if only the analog signal is used A shielded cable is recommended for HART communication Observe grounding concept of the plant In the case of the...

Page 20: ...d power supply 5 Internal ground connection 6 External ground connection 7 Shielded signal cable recommended for HART protocol The terminals for signal cable connection 1 and 2 are protected against r...

Page 21: ...connection Notes Does the supply voltage match the information on the nameplate Head transmitter U 11 to 42 VDC DIN rail transmitter U 12 to 42 VDC SIL mode U 11 to 32 VDC for the head transmitter or...

Page 22: ...splay to the transmitter 6 1 2 Display elements Head transmitter 1 2 3 4 5 6 7 A0008549 15 Optional LC display for head transmitter Item no Function Description 1 Displays the TAG TAG 32 characters lo...

Page 23: ...message DIN rail transmitter The DIN rail transmitter version does not have an interface to the LC display and therefore does not have a local display either Two LEDs on the front indicate the device...

Page 24: ...r in the correct position The head transmitter accepts the settings within one second 5 Secure the cover back onto the terminal head or field housing Switching write protection on off Write protection...

Page 25: ...y with this instruction can result in damage to parts of the electronics The configuration of device specific parameters is described in detail in the Operating Instructions for the device 7 Commissio...

Page 26: ...configuration If the device is locked and the parameter settings cannot be changed it must first be enabled via the hardware or software lock The device is write protected if the lock symbol appears...

Page 27: ......

Page 28: ...www addresses endress com...