Proline Promass 80
Wiring
Hauser
27
a0004582
Fig. 20:
Connecting the transmitter (aluminum field housing); cable cross-section: max. 2.5 mm
a
Cable for power supply: 85 to 260 V AC, 20 to 55 V AC, 16 to 62 V DC
Terminal No. 1: L1 for AC, L+ for DC
Terminal No. 2: N for AC, L- for DC
b
Signal cable: Terminals Nos. 20–27
c
Ground terminal for protective ground
d
Ground terminal for signal cable shield
e
Service adapter for connecting service interface FXA 193 (Fieldcheck, FieldCare)
f
Cover of the connection compartment
g
Securing clamp
a0004584
Fig. 21:
Connecting the transmitter (stainless steel field housing); cable cross-section: max. 2.5 mm
a
Cable for power supply: 85 to 260 V AC, 20 to 55 V AC, 16 to 62 V DC
Terminal No. 1: L1 for AC, L+ for DC
Terminal No. 2: N for AC, L- for DC
b
Signal cable: Terminals Nos. 20–27
c
Ground terminal for protective ground
d
Ground terminal for signal cable shield
e
Service adapter for connecting service interface FXA193 (Fieldcheck, FieldCare)
f
Cover of the connection compartment
b
b
c
d
a
a
2
1
– 27
– 25
– 23
– 21
+ 26
+ 24
+ 22
+ 20
L1 (L+)
N (L-)
g
f
e
b
c
d
a
2
1
L1 (L+)
N (L-)
f
b
a
e
– 27
– 25
– 23
– 21
+ 26
+ 24
+ 22
+ 20