Proline Promag P 500 HART
Technical data
Hauser
195
External WLAN antenna
• Antenna: ASA plastic (acrylic ester-styrene-acrylonitrile) and nickel-plated brass
• Adapter: Stainless steel and nickel-plated brass
• Cable: Polyethylene
• Plug: Nickel-plated brass
• Angle bracket: Stainless steel
Ground disks
Stainless steel, 1.4435 (F316L); Alloy C22, 2.4602 (UNS N06022); tantalum; titanium
Fitted electrodes
Measuring electrodes, reference electrodes and electrodes for empty pipe detection:
• Standard: stainless steel, 1.4435 (F316L); Alloy C22, 2.4602 (UNS N06022); tantalum,
titanium
• Optional: only platinum measuring electrodes
Surface roughness
Stainless steel electrodes, 1.4435 (F316L); Alloy C22, 2.4602 (UNS N06022); platinum;
tantalum; titanium:
≤ 0.3 to 0.5 µm (11.8 to 19.7 µin)
(All data relate to parts in contact with fluid)
Liner with PFA:
≤ 0.4 µm (15.7 µin)
(All data relate to parts in contact with fluid)
16.11 Operability
Languages
Can be operated in the following languages:
• Via local operation
English, German, French, Spanish, Italian, Dutch, Portuguese, Polish, Russian, Turkish,
Chinese, Japanese, Korean, Bahasa (Indonesian), Vietnamese, Czech, Swedish
• Via Web browser
English, German, French, Spanish, Italian, Dutch, Portuguese, Polish, Russian, Turkish,
Chinese, Japanese, Korean, Bahasa (Indonesian), Vietnamese, Czech, Swedish
• Via "FieldCare", "DeviceCare" operating tool: English, German, French, Spanish, Italian,
Chinese, Japanese
Local operation
Via display module
Two display modules are available:
• Order code for "Display; operation", option
F
"4-line, illuminated, graphic display; touch
control"
• Order code for "Display; operation", option
G
"4-line, illuminated, graphic display; touch
c WLAN"
Information about WLAN interface → 84
Summary of Contents for Hart Proline Promag P 500