Proline Promag P 500 HART
Commissioning
Hauser
113
Device type
Manufacturer ID
Burst command
Slot number
Timeout
Failure mode
Failure value
"Configuration" submenu
Navigation
"Expert" menu → Communication → HART input → Configuration
Parameter overview with brief description
Parameter
Prerequisite
Description
Selection / User
entry
Factory setting
Capture mode
–
Select capture mode via burst
or master communication.
• Off
• Burst network
• Master network
Off
Device ID
The
Master network
option is
selected in the
Capture mode
parameter.
Enter device ID of external
device.
6-digit value:
• Via local
operation: enter as
hexadecimal or
decimal number
• Via operating tool:
enter as decimal
number
0
Device type
In the
Capture mode
parameter, the
Master
network
option is selected.
Enter device type of external
device.
2-digit hexadecimal
number
0x00
Manufacturer ID
The
Master network
option is
selected in the
Capture mode
parameter.
Enter manufacture ID of
external device.
2-digit value:
• Via local
operation: enter as
hexadecimal or
decimal number
• Via operating tool:
enter as decimal
number
0
Burst command
The
Burst network
option or
the
Master network
option
are selected in the
Capture
mode
parameter.
Select command to read in
external process variable.
• Command 1
• Command 3
• Command 9
• Command 33
Command 1
Slot number
The
Burst network
option or
the
Master network
option is
selected in the
Capture mode
parameter.
Define position of external
process variable in burst
command.
1 to 8
1