Deltapilot S FMB70

About this document

Hauser

3

2.2  

Symbols used

2.2.1  

Safety symbols

DANGER

This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in

serious or fatal injury.

WARNING

This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in

serious or fatal injury.

CAUTION

This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in

minor or medium injury.

NOTICE

This symbol contains information on procedures and other facts which do not result in

personal injury.

2.2.2  

Electrical symbols

Ground connection
A grounded terminal which, as far as the operator is concerned, is grounded via a grounding

system.

 

Protective earth (PE)

Ground terminals that must be connected to ground prior to establishing any other

connections.
The ground terminals are located on the interior and exterior of the device:

• Interior ground terminal: protective earth is connected to the mains supply.

• Exterior ground terminal: device is connected to the plant grounding system.

2.2.3  

Symbols for certain types of information and graphics

 Permitted

Procedures, processes or actions that are permitted

 Forbidden

Procedures, processes or actions that are forbidden

 Tip

Indicates additional information

Reference to documentation

A

Reference to page

Reference to graphic

Summary of Contents for FMB70

Page 1: ...substitute for the Operating Instructions pertaining to the device Detailed information about the device can be found in the Operating Instructions and the additional documentation Available for all...

Page 2: ...rd cd Ser no www endress com deviceviewer Endress Hauser Operations App XXXXXXXXXXXX XXXXX XXXXXX XXX XXXX XX Serial number 1 3 2 A0023555 2 About this document 2 1 Document function The Brief Operati...

Page 3: ...injury 2 2 2 Electrical symbols Ground connection A grounded terminal which as far as the operator is concerned is grounded via a grounding system Protective earth PE Ground terminals that must be con...

Page 4: ...o perform this function and task Are authorized by the plant owner operator Are familiar with federal national regulations Before starting work read and understand the instructions in the manual and s...

Page 5: ...e Use original spare parts and accessories from Endress Hauser only Hazardous area To eliminate a danger for persons or for the facility when the device is used in the hazardous area e g explosion pro...

Page 6: ...can be identified in the following ways Nameplate specifications Extended order code with breakdown of the device features on the delivery note Enter serial number from nameplates in W M Device Viewe...

Page 7: ...0 to 30 Nm 14 75 to 22 13 lbf ft 5 2 Mounting the device Due to the orientation of the Deltapilot S a zero point shift may occur i e when the vessel is empty the measured value does not display zero Y...

Page 8: ...compensation and GORE TEX filter 1 free from contamination and water Do not clean or touch process membranes with hard or pointed objects The device must be installed as follows in order to comply wi...

Page 9: ...toff device above the tapping point so that any condensate can flow into the process Pressure measurement in vapors Mount the Deltapilot S with the water pocket pipe above the tapping point Fill the w...

Page 10: ...be tightened finger tight 2 Nm 1 48 lbf ft to the stop to ensure that the covers are securely seated and leak tight 6 Electrical connection 6 1 Connecting the device LWARNING Risk of electric shock If...

Page 11: ...est Test 4 20mA Test 1 8 6 7 2 3 4 5 A0019989 1 Housing 2 Minimum supply voltage 10 5 V DC jumper is set as illustrated in the diagram 2 Minimum supply voltage 11 5 V DC jumper is set to the Test posi...

Page 12: ...lectrical connection for devices with Harting plug Han7D B View of the plug in connection on the device Brown Green yellow Blue 6 1 2 Connection of devices with M12 plug p 21 PIN 2 1 3 4 A0011175 1 Si...

Page 13: ...sion for non hazardous area 11 5 to 45 V DC 10 5 to 45 V DC Measuring the 4 to 20 mA test signal A 4 to 20 mA test signal can be measured via the positive and test terminal without interruption The mi...

Page 14: ...10 5 11 U V 40 40 45 45 1282 1260 1500 1478 847 826 413 391 Test A A 1 RLmax U 11 V 23 mA 4 2 3 1 2 3 W RLmax RLmax U 1 V 2 23 mA 4 W RLmax U V RLmax U 1 V 0 5 23 mA 4 RLmax U 1 V 1 5 23 mA 4 W RLmax...

Page 15: ...hnical data and instructions is included with all Ex systems as standard 7 Operation options Feature 20 Output operation in the order code provides you with information on the operating options availa...

Page 16: ...connected To perform the corresponding function press the key or key combination for at least 3 s Press the key combination for at least 6 s for a reset Meaning Adopt lower range value A reference pre...

Page 17: ...are displayed if the pressure is too high If a pressure that is greater than the maximum permitted pressure is present at the device messages E115 sensor overpressure and E727 sensor pressure error o...

Page 18: ...mA value SET URV 100 0 corresponds to 20 mA value Operation must be unlocked The pressure applied must be within the nominal pressure limits of the sensor See information on the nameplate LEVEL SELECT...

Page 19: ...g modes and guides you through the most important basic functions You specify which Quick Setup menu should be displayed with the setting in the MEASURING MODE parameter For a detailed parameter descr...

Page 20: ...www addresses endress com 71566247 71566247...

Reviews: