Fieldgate FXA720
5 Getting Started
Hauser
25
For two and three channel
versions
9. Now configure the other channels of your Fieldgate by pressing the
"Add".
button.
– Follow the sequence from Step 3 to Step 5 inclusive.
– Enter the same IP address: Fieldgate requires only one IP address for operation.
– Select
"Bus 2"
or
"Bus 3"
as appropriate.
10.Click "
Finish
" to accept the default timeout settings and end the configuration.
Caution:
Timeout settings should be changed by PROFIBUS specialists only
11.On completion, the new node will be added to the network tree:
– Press
"Apply"
to store the configuration
Note: the screenshot shows the two channel version.
12.When all channels have been configured, press
"OK"
to store the configuration and close the
configuration window.