background image

Basic safety instructions

Field Xpert SMT50

8

Hauser

The operating personnel must fulfill the following requirements:

Are instructed and authorized according to the requirements of the task by the facility's

owner-operator.

Follow the instructions in this manual.

2.2  

Designated use

The tablet PC for device configuration enables mobile plant asset management. It is suitable

for commissioning and maintenance staff to manage field instruments with a digital

communication interface and to record progress. This tablet PC is designed as a complete

solution and is an easy-to-use, touch-enabled tool which can be used to manage field

instruments during their entire life cycle. It provides extensive, pre-installed driver libraries

and offers access to the "Industrial Internet of Things" as well as to information and

documentation during the entire life cycle of the device. The tablet PC offers a modern

software user interface and the option of online updates based on a secure Microsoft

Windows 10 multi-functional environment.

2.3  

Workplace safety

The tablet PC is used for device configuration. Incorrect configurations may lead to unwanted

or hazardous situations in a plant. The device configuration software is already installed on

the tablet PC upon delivery. These Operating Instructions describe how to commission and

operate the tablet PC.

• Commissioning

• Operation

2.4  

Operational safety

Risk of injury!

Operate the device in proper technical condition and fail-safe condition only.

The operator is responsible for interference-free operation of the device.

Modifications to the device

Unauthorized modifications to the device are not permitted and can lead to unforeseeable

dangers:

If, despite this, modifications are required, consult with Hauser.

Repair

To ensure continued operational safety and reliability:

Carry out repairs on the device only if they are expressly permitted.

Observe federal/national regulations pertaining to repair of an electrical device.

Use only original spare parts and accessories from the manufacturer.

2.5  

Product safety

The tablet PC is designed in accordance with good engineering practice to meet state-of-the-

art safety requirements, has been tested, and left the factory in a condition in which it is safe

to operate.

Summary of Contents for Field Xpert SMT50

Page 1: ...Products Solutions Services Operating Instructions Field Xpert SMT50 Universal high performance tablet PC for device configuration BA02053S 04 EN 01 20 71491472 2020 07 31...

Page 2: ...Revision history Field Xpert SMT50 2 Endress Hauser Revision history Product version Operating Instructions Changes Comments 1 05 xx BA02053S 04 EN 01 20...

Page 3: ...ftware 15 5 3 Updating the software 15 5 4 Removing the software 16 6 Operation 16 6 1 Shutting down the tablet PC 16 6 2 Switching off the tablet PC 17 6 3 Security screen 17 7 Commissioning 17 7 1 I...

Page 4: ...s or fatal injury WARNING This symbol alerts you to a dangerous situation Failure to avoid this situation can result in serious or fatal injury CAUTION This symbol alerts you to a dangerous situation...

Page 5: ...2 3 Field Xpert icons Symbol Meaning Switch tablet on and off Windows button Wireless communication WLAN WWAN GPS Bluetooth Battery Scanner App Open the home screen of the device configuration softwa...

Page 6: ...t with wizard manual connection Connect with Endress Hauser WLAN and Bluetooth devices RFID Cloud Favorites Keypad Camera Link to Netilion Library Attach photos and PDFs to an asset in Netilion Librar...

Page 7: ...trademark of the IO Link Community c o PROFIBUS User Organization PNO Karlsruhe Germany www io link com All other brand and product names are trademarks or registered trademarks of the companies and...

Page 8: ...2 3 Workplace safety The tablet PC is used for device configuration Incorrect configurations may lead to unwanted or hazardous situations in a plant The device configuration software is already insta...

Page 9: ...ption With an ultra compact form factor the tablet PC meets the most demanding requirements such as ingress protection IP65 and shock resistance MIL STD 810G The additional screen protector offers com...

Page 10: ...DB 9 serial COM 1 RS 232 fixed Standard 9 Slot for Kensington lock 10 Dock connector 11 Corning Gorilla Glass 12 LAN DC socket 13 USB 3 0 USB 2 0 14 Audio out 3 5mm USB type C mini HDMI Component Des...

Page 11: ...ttery SIM and SD card slot are located below the battery 2 Rear camera 3 Loudspeaker left side 4 Loudspeaker right side 5 Button F Torch Component Description Camera flash For additional lighting in p...

Page 12: ...al communication interface and to record progress This tablet PC is designed as a complete solution and is an easy to use finger operated tool which can be used to manage field instruments during thei...

Page 13: ...count function Activating the device configuration software package 1 Double click Field Xpert on the start screen The software licensing page opens 2 Click Activate Software The dialog box where you...

Page 14: ...ng is missing Retain all the accompanying documents The device may not be put into operation if the contents are found to be damaged beforehand In this case please contact your Endress Hauser Sales Ce...

Page 15: ...al packaging when transporting the product 4 3 1 Storage temperature 20 to 60 C 4 to 140 F 5 Installation 5 1 System requirements The software is already installed on the tablet PC upon delivery 5 2 I...

Page 16: ...Always place the device on a stable surface Do not cover the ventilation opening or block it by other objects Keep the device away from liquids Do not expose the device to direct sunshine or very dus...

Page 17: ...t PC is in sleep mode 6 3 Security screen 1 Press key combination Ctrl Alt Del Windows security screen appears 2 Select an action Possible actions Lock device Change to another user Logout Change pass...

Page 18: ...n the battery cover by pressing the slide control on the rear of the tablet to the left 2 Take the enclosed plastic lever and use it to open the battery cover 3 Insert the battery fit the battery cove...

Page 19: ...adapter Place the device sufficiently close to a power outlet that the power cable can still reach the outlet Only operate the device with the type of power source indicated on the device nameplate Di...

Page 20: ...the first time the device configuration software is started Double click Field Xpert on the start screen The device configuration software starts 8 2 Establishing a connection to the device A connecti...

Page 21: ...onnection Modems interfaces HART Commubox FXA195 4 to 20 mA MACTek Bluetooth modem 4 to 20 mA Memograph RSG45 4 to 20 mA MACTek USB modem 4 to 20 mA FieldPort SFP50 Fieldgate SFG250 Tank Scanner NXA82...

Page 22: ...Fieldgate SFG500 FOUNDATION Fieldbus NI USB FieldPort SFP50 Softing FFusb Modbus Modbus serial Endress Hauser service interfaces Commubox FXA291 CDI Commubox FXA291 IPC ISS PCP Commubox FXA193 IPC ISS...

Page 23: ...23 Communication protocol Connection Modems interfaces Wi Fi A0041855 Endress Hauser Wi Fi devices IO Link FieldPort SFP20 Automatic connection Click the icon The device configuration software establ...

Page 24: ...Operation Field Xpert SMT50 24 Endress Hauser Wizard connection 1 Click the icon An overview of all the protocols available opens...

Page 25: ...Field Xpert SMT50 Operation Endress Hauser 25 2 Select a communication protocol An overview of all the modems available opens 3 Select a modem The device can now be configured...

Page 26: ...Wireless connection Click the icon The live list appears with all available Endress Hauser Wi Fi and Bluetooth devices This list can be filtered for Wi Fi and Bluetooth devices Bluetooth connection 1...

Page 27: ...er admin for the username and the password and click Login The dialog box for initial commissioning opens The initial password corresponds to the serial number of the device WLAN connection 1 Click th...

Page 28: ...be configured The initial password corresponds to the serial number of the device Tap Click here to connect to establish the connection directly via an IP address 8 3 Information and software settings...

Page 29: ...ts the offline view If other device drivers DTMs are required they can be installed additionally After an automatic or manual update these drivers appear in the DTM catalog 8 3 2 Event log Click the E...

Page 30: ...orites tab or the icon An overview of all the favorites opens 8 3 4 Managing reports 1 Click the Manage reports tab An overview with the Manage saved device reports folder opens 2 Click the Manage sav...

Page 31: ...ss Hauser 31 8 3 5 Firmware Click the Firmware tab An overview of the firmware opens 8 3 6 Settings Language 1 Click the Settings tab The Language tab opens with an overview of all the languages avail...

Page 32: ...iguration software closes 4 Restart the device configuration software The selected language is saved Connection Click the Connection tab An overview of all the connections opens The Connectivity tab i...

Page 33: ...the Netilion tab An overview of data storage settings opens 8 4 Additional information about the software Click the icon An overview of all the additional information opens 8 4 1 License Click the Lic...

Page 34: ...maintenance contract has expired The customer receives a notification in the Field Xpert software upon successful completion of the order 8 4 2 Updating Click the Update tab The window with the update...

Page 35: ...Fieldgate PAM SFG600 HART via PROFINET The Fieldgate PAM SFG600 is a device configuration management gateway and supports HART devices via PROFINET networks The HART devices must have a unique device...

Page 36: ...Operation Field Xpert SMT50 36 Endress Hauser Click the icon The Communication server overview opens...

Page 37: ...k the icon in the status bar The Sign in to Netilion Library dialog box opens 2 Click Sign up 3 Choose subscription Basic Plus Premium 4 Sign in with the Netilion data The tablet searches for DTMs in...

Page 38: ...the Netilion Library This function is possible with HART PROFIBUS FOUNDATION Fieldbus and IO Link devices as well as via the Endress Hauser Service interface CDI 1 Click the icon in the status bar The...

Page 39: ...and open the DTM Click the icon The dialog box opens 2 Select the file type 3 Select the photo from a directory in Field Xpert 4 Click Yes The photo is uploaded to the Netilion Library for the existin...

Page 40: ...nned devices new photos device reports PDF and parameter records are automatically saved in the offline cache They are uploaded automatically once a new Internet connection is established 1 Click the...

Page 41: ...ta storage information dialog box opens 3 Click Show assets An overview of all assets and documents appears 4 Click the icon to remove assets and documents 5 Click the Online tab and sign in 6 Click U...

Page 42: ...on in the status bar The Netilion Library dialog box opens 2 Sign in to the Netilion Library 8 8 Scanner App 1 Click the icon in the status bar The wizard to create a device in the Netilion Library is...

Page 43: ...ed all the steps it starts again automatically so that another device can be entered The Scanner App also works in offline mode Data already saved in the Netilion Library are not available offline 8 9...

Page 44: ...lt as a PDF A dialog appears where you can select the storage location for the PDF file 5 Select the storage location and click Save A dialog for saving in the Netilion Library appears 6 Click Yes A d...

Page 45: ...the status bar The RFID TAG Editor dialog box opens 2 Plug in the RFID scanner 3 Click Read tag 4 Place the RFID tag on the scanner and click Device Viewer The Device Viewer opens in Internet Explorer...

Page 46: ...ommended by the manufacturer The battery capacity gradually diminishes over time depending on how the battery is used The battery can be replaced after 18 to 24 months Dispose of used batteries in acc...

Page 47: ...Return The device must be returned if the wrong device has been ordered or delivered or if the device is in need of repair As an ISO certified company and also due to legal regulations Endress Hauser...

Page 48: ...l This product contains a lithium ion battery or a nickel metal hydride battery These batteries must be disposed of in the correct manner Please contact your local environmental protection authority f...

Page 49: ...ng station 2 x USB 1 x 1 Gbit Ethernet 1 x RS232 Battery charger Device cable EU US UK CH IT AU Please contact your Endress Hauser Sales Center for detailed information on accessories www addresses en...

Page 50: ......

Page 51: ......

Page 52: ...www addresses endress com...