background image

TI257P/00/en
71034474

Technical Information

Deltapilot S DB50/50L/51/52/53

Hydrostatic Level Measurement
Pressure sensor with CONTITE

TM

 measuring cell; 

waterproof, climatic-proofed, long-term stability; for food, fresh 
water and wastewater, chemical and pharmaceutical products

Application

The devices in the Deltapilot S product family are used 
for continuous level measurement in all liquid and paste-
like media. They are used in both the chemical, 
pharmaceutical and food industry as well as in the water 
and wastewater sector.

Switching units perfectly in line with the application:
• Determine the level, volume, differential pressure, 

density and product weight

• Control limit contacts
• Integrate the measuring point in various automation 

systems.

Your benefits

• Hermetically sealed CONTITE

TM

 measuring cell:

– Climatic-proofed and with high long-term stability
– Maximum linearity (better than 0.1 % of the set 

measuring range)

– Minimum temperature effects 

(better than 0.1%/10 K).

• Compact, rod or cable versions available
• Separate mounting of housing and electronic insert 

(IP 68 protection at the measuring point)

• Easy and comfortable operation:

– Onsite with display and operating module 
– Operation via communication

• Replaceable electronic inserts:

– 4 to 20 mA HART
– PROFIBUS PA
– FOUNDATION Fieldbus
– Analog output
– PFM

Summary of Contents for Deltapilot S DB50

Page 1: ...fectly in line with the application Determine the level volume differential pressure density and product weight Control limit contacts Integrate the measuring point in various automation systems Your benefits Hermetically sealed CONTITETM measuring cell Climatic proofed and with high long term stability Maximum linearity better than 0 1 of the set measuring range Minimum temperature effects better...

Page 2: ...cations 19 Special measuring cells for substances with hydrogen formation 19 Special measuring cell for acids alkalis or sea water 19 Operating conditions environment 20 Ambient temperature range 20 Ambient temperature limits 20 Storage temperature range 20 Vibration resistance 20 Degree of protection 20 Electromagnetic compatibility EMC 20 Overvoltage protection 20 Operating conditions process 21...

Page 3: ...6 Mounting bracket 56 Extension cable shortening kit 56 Suspension clamp 56 Protective cover 57 Welding flanges 57 Welding neck adapter for universal process adapter 58 Welding neck adapter thread ISO G 1 1 2 58 Adapter 58 Documentation 59 Field of Activities 59 Technical Information on switching unit 59 Operating Instructions 59 Safety Instructions 59 Installation Drawings Control Drawings 59 Ove...

Page 4: ...o 7874 inch 1 Measuring ranges from 100 to 100 mbar to 900 to 10000 mbar US version from 1 5 to 1 5 psi to 13 to 150 psi Max turn down 10 1 Process temperature 10 to 100 C 14 to 212 F 10 to 100 C 14 to 212 F 135 C 275 F for 30 minutes 10 to 80 C 14 to 176 F 10 to 80 C 14 to 176 F 10 to 80 C 14 to 176 F Supply voltage Analog 0 2 to 1 2 mA 15 to 20 V DC PFM 14 to 16 V DC EEx ia 14 to 19 2 V DC 4 to ...

Page 5: ...A or EHEDG approvals P01 DB5xxxxx 12 xx xx xx 004 DB53 A for the water and wastewater industry The housing with the electronic insert is mounted outside shafts and tanks in such a way that it is protected from flooding The extension cable is secured with a suspension clamp Electronic inserts with an integrated surge arrester provide protection against overvoltage if lightning strikes The stainless...

Page 6: ...s the core of Deltapilot S In contrast to conventional gauge pressure sensors the precision measuring element 2 in the CONTITE measuring cell is absolutely protected between the process diaphragm 3 and the measuring diaphragm 1 Thanks to this hermetic sealing of the measuring element the CONTITE measuring cell is absolutely insensitive to condensate condensation and aggressive gases The pressure a...

Page 7: ...ressure hydrostatic pressure and top pressure 2 Probe 2 measures the top pressure 3 The signal processing unit determines the difference in pressure and uses this to calculate the level Note When selecting the Deltapilot S probes make sure you select large enough measuring ranges see example The measuring diaphragm of probe 2 must not be flooded This generates additional hydrostatic pressure which...

Page 8: ... two measured values p1 and p2 and the distance Δh Level measurement with automatic density correction with changing media in the tank Level measurement with automatic density correction is possible in conjunction with a limit switch such as Liquiphant and a PLC The limit switch always switches at the same level In the switch point the signal processing unit determines the corrected density from t...

Page 9: ...g Instructions BA179F Measuring system with PFM FEB17 P The electronic insert returns a pulse frequency modulated signal of 200 to 1200 Hz The evaluation and operating unit Prolevel FMB662 provides power to the electronic insert and converts the PFM signal of the probe to a standardized current or voltage signal See also Technical Information TI234F and Operating Instructions BA144F Measuring syst...

Page 10: ...ery parameter directly at the place of measurement Dry calibration linearization and operation enabling and disabling are possible without any further tools P01 DB5xxxxx 07 xx xx xx 001 User interface of the electronic insert with the FHB20 display and operating module 1 4 1 2 digit display of measured values and parameters 2 Current matrix position 3 Bar graph of the measured value 4 Operating ma...

Page 11: ...nic insert FEB22 P 4 to 20 mA HART 1 Operating keys for empty and full calibration calibration with partially full tanks lock unlock operation and reset 2 Green LED flashes when accepting the value for empty and full calibration during a reset and if operation is locked or unlocked 3 Slot for optional FHB20 display and operating module 4 Slot for the DAT module P01 DB5xxxxx 19 xx xx xx 004 Electro...

Page 12: ...tation and recording of measured values with a line recorder Connection option HART via Commubox FXA191 with the serial interface RS 232 C of a computer or via Commubox FXA195 with the USB interface of a computer PROFIBUS PA via segment coupler and PROFIBUS interface card Remote operation FOUNDATION Fieldbus An FF configuration program is required to integrate a device with FOUNDATION Fieldbus sig...

Page 13: ...n Upper range value URV lower range value LRV 40 mbar 0 mbar Set span 40 mbar This span is based on the zero point P01 DBxxxxxx 05 xx xx xx 001 Example 400 mbar measuring cell Case 2 Lower range value LRV Upper range value URV Example Lower range value LRV 200 mbar Upper range value URV 0 bar Nominal value URL 400 mbar Turn down Nominal value lower range value LRV 400 mbar 200 mbar TD 2 1 Set span...

Page 14: ...y Min onsite display 19999 Max onsite display 19999 Hold last measured value is held FOUNDATION Fieldbus Output signal last measured value is held status change from Uncertain or Bad Options configurable in the Transducer Block for the Measured value parameter and the onsite display Min onsite display 19999 Max onsite display 19999 Hold last measured value is held Load Sensitivity PFM FEB17 P Damp...

Page 15: ...tion currents in the system only ground the shielding at one end preferably at the Deltapilot S probe 4 to 20 mA HART electronics FEB22 P P01 DB5xxxxx 04 xx xx xx 005 0 2 to 1 2 mA analog electronics FEB11 P The twin core cable must be connected to terminals 2 and 3 PFM electronics FEB17 P The twin core cable must be connected to terminals 2 and 3 PRODFIBUS PA electronics FEB24 P The twin core cab...

Page 16: ...C Version for non hazardous areas and electronics with overvoltage protection 9 6 to 32 V DC FOUNDATION Fieldbus Version for non hazardous areas 9 to 32 V DC Current consumption PROFIBUS PA 10 mA 1 mA FOUNDATION Fieldbus 11 mA 1 mA Switch on current 0 1 to 1 2 mA analog PFM and 4 to 20 mA HART 100 mA for 30 V pulse width half life 20 ms PROFIBUS PA and FOUNDATION Fieldbus Switch on current corresp...

Page 17: ...ation temperature 25 C 77 F Position during calibration Zero point increase 90 of measuring range Long term stability 0 1 of URL1 per 6 months Linearity Linearity as per the limit point method 0 2 of the set span1 Optional 0 1 of the set span1 Hysteresis 0 1 of URL1 Influence of ambient temperature 0 01 10 K of URL1 Influence of medium temperature 0 1 10 K of URL1 DB50 A DB50L DB50S DB51 A DB 52 A...

Page 18: ...uld be at least 5 cm under this Supplementary installation instructions Process diaphragm Do not use sharp or hard objects to handle or clean the process diaphragm Build up has no effect on the measurement result as long it is porous and does not present a mechanical load on the diaphragm of the pressure measuring cell The process diaphragm on all Detapilot S rod and cable extension is protected a...

Page 19: ...using adapter and mounting bracket 1 Housing adapter 2 Mounting bracket for pipe and wall mounting 3 Pipe bend Note When mounting observe a bending radius of at least 200 mm Special measuring cells for substances with hydrogen formation In the case of materials in which hydrogen formation occurs e g digested sludge hydrogen atoms can diffuse through the metal diaphragm This can result in incorrect...

Page 20: ... overshot here Storage temperature range 40 to 85 C 40 to 185 F Vibration resistance 10 to 55 Hz 2 g as per DIN EN 60068 2 6 Degree of protection See Page 37 ff feature 80 Housing Cable entry Housing IP 66 NEMA 4X Housing adapter IP 68 1 mH2O for 24 h Electromagnetic compatibility EMC Interference emission as per EN 61326 electrical device B interference immunity as per EN 61326 appendix A industr...

Page 21: ...ng range section Mechanical construction Dimensions of housing P01 DB5xxxxx 06 xx xx xx 008 Deltapilot S housing versions 1 Aluminum housing 2 Polyester housing 3 Stainless steel housing Dimensions written in italics apply to devices with a cover including a sight glass Devices with the FHB20 onsite display are always supplied with a cover with a sight glass Device Process temperature range DB50 A...

Page 22: ...rier for use in hazardous areas Zone 0 Installation height H devices with a thread 146 22 5 25 H 46 7 22 5 25 H 25 SW 60 SW 60 Cover Aluminum housing mm Polyester housing mm Stainless steel housing mm Without a flame barrier Flat 205 2 213 2 204 2 High with sight glass 1 1 Devices with the FHB20 display and operating module are always supplied with a high cover or with a cover with a sight glass 2...

Page 23: ...16 88 3 4 18 110 2 3 21 AISI 316L DN 50 PN 10 16 B1 C 165 18 102 3 4 18 125 3 0 22 AISI 316L DN 80 PN 10 16 B1 C 200 24 138 3 8 18 160 4 8 23 AISI 316L DN 100 PN 10 16 B1 C 220 20 158 3 8 18 180 6 0 1 AISI 316L 1 4435 2 Designation as per DIN 2526 in brackets 3 Housing weight see Page 32 Flange Screwholes Version Material 1 Nominal diameter Class Diameter Thickness Raised face diameter Raised face...

Page 24: ... 5 7L AISI 316L 100 A 10 K 210 18 151 2 8 19 175 4 6 1 AISI 316L 1 4435 2 Weight incl pipe housing weight see Page 32 Cover Aluminum housing mm Polyester housing mm Stainless steel housing mm Without a flame barrier Flat 201 flange thickness b 201 flange thickness b 189 flange thickness b High with sight glass 1 1 Devices with the FHB20 display and operating module are always supplied with a high ...

Page 25: ...ss adapter Tri Clamp ISO 2852 P01 DB5xxxxx 06 xx xx xx 015 Process connection DB50L DB50S version 50 Tri Clamp ISO 2852 DN 40 DN 51 2 DIN 32676 DN 50 EHEDG 3A Material AISI 316L 1 4435 surface roughness of surfaces in contact with the medium Ra 0 8 μm as standard Lower surface roughness on request ø43 5 ø63 ø43 5 ø63 H H Cover Aluminum housing mm Polyester housing mm Stainless steel housing mm Uni...

Page 26: ... DRD 65 mm PN 25 EHEDG 3A 5 Version 40 DIN 11851 DN 40 PN 40 6 Version 41 DIN 11851 DN 50 PN 40 Installation height H devices with universal process adapter Tri Clamp or hygienic connection H 78 ø35 8 10 ø56 Rd 65x1 6 H 92 11 ø68 Rd 78x1 6 ø35 8 4 x ø11 5 ø65 ø84 H ø35 8 ø84 ø105 ø35 8 ø68 ø84 H H ø35 8 ø77 ø65 3 ø54 2 ø65 ø35 8 H ø84 Rd 70x1 6 Cover Aluminum housing mm Polyester housing mm Stainl...

Page 27: ...eas Zone 0 H For installation height H see Page 22 EN DIN ANSI and JIS flanges P01 DB5xxxxx 06 xx xx xx 027 DB51 A rod version with flange 1 DB51 A flange without flame barrier 2 DB51 A flange with flame barrier flame barrier for use in hazardous areas Zone 0 H For installation height H see Page 24 For process connection dimensions see Page 23 ff 146 22 5 25 H SW 60 ø42 5 46 7 22 5 25 H ø17 2 230 ...

Page 28: ...1 1 2 and 1 1 2 NPT without flame barrier 2 DB52 A thread G 1 1 2 and 1 1 2 NPT with flame barrier flame barrier for use in hazardous areas Zone 0 3 Clamp for clamping fixture H For installation height H see Page 22 L Probe length Without approval EEx nA II T6 0 5 to 200 m 20 to 7874 inch EEx ia IIC T6 FM IS CSA IS 0 5 to 100 m 20 to 3937 inch 46 7 22 5 25 ø10 4 ø42 5 257 L H SW 60 146 22 5 25 H S...

Page 29: ...2 DB52 A flange with flame barrier flame barrier for use in hazardous areas Zone 0 3 Clamp for clamping fixture H For installation height H see Page 24 L Probe length Without approval EEx nA II T6 0 5 to 200 m 20 to 7874 inch EEx ia IIC T6 FM IS CSA IS 0 5 to 100 m 20 to 3937 inch For process connection dimensions see Page 23 ff k D f g2 55 7 b H 185 b H H g ...

Page 30: ...tube L Probe length Without approval EEx nA II T6 0 5 to 200 m 20 to 7874 inch EEx ia IIC T6 FM IS CSA IS 0 5 to 100 m 20 to 3937 inch Dimension A Dimension H 66 280 H max 241 A max 286 ø86 75 ø42 5 2 ø6 L ø10 4 240 Cover Aluminum housing Polyester housing Stainless steel housing Flat 265 mm 273 mm 264 mm High with sight glass 286 mm 273 mm 280 mm Cover Aluminum housing Polyester housing Stainless...

Page 31: ...amping fixture 5 Measuring cell tube L Probe length Note For DB50 DB50L DB51 DB52 order the housing adapter and the mounting bracket via feature 90 Additional option or subsequently as an accessory See also Page 19 and Page 56 Housing adapter with mounting bracket section When using a housing adapter in the EEx ia FM IS or CSA IS area the total cable length connecting cable L1 extension cable L2 m...

Page 32: ...With high cover incl electronic insert 1 15 kg 0 7 kg 1 0 kg Process connection incl sensor Weight Threaded connection without a flame barrier incl sensor 0 8 kg Threaded connection with a flame barrier incl sensor 1 35 kg Flange connection without a flame barrier incl sensor without a flange 0 45 kg Flange connection with a flame barrier incl sensor without a flange 1 0 kg Process connection incl...

Page 33: ...amp weight of measuring cell tube Process connection incl sensor Weight Pipe incl cable 0 77 kg m Threaded connection without a flame barrier incl measuring cell tube and sensor 1 65 kg Threaded connection with a flame barrier incl measuring cell tube and sensor 2 2 kg Flange connection without a flame barrier incl measuring cell tube and sensor without a flange 1 3 kg Flange connection with a fla...

Page 34: ... plastic Clamp for clamping fixture for DB52 A PFA perflouralkoxy plastic AISI 304 1 4301 Housing adapter and pipe bend Housing adapter AISI 316L 1 4435 and AISI 316 Ti 1 4571 Multi core cable with steel braiding PE insulation Pipe bend AISI 316 Ti 1 4571 and AISI 321 1 4541 Cable gland CuZn nickel plated O ring NBR Sealing insert TPE V O ring EPDM Mounting bracket AISI 304 1 4301 Accessories Weig...

Page 35: ...ion Control Drawings sections Overfill protection WHG German Water Resources Act Seismic test DB53 with FEB22 electronic insert passed in accordance with IEEE 344 1987 Marine approval DB50 DB50L DB52 and DB53 with FEB17 electronic insert German Lloyd certificate No 99350 97 HH Standards and guidelines DIN EN 60770 IEC 60770 Transmitters for controlling in systems used in industrial process technol...

Page 36: ...0 16 B1 AISI 316L 21 DN 50 PN 10 16 B1 AISI 316L 22 DN 80 PN 10 16 B1 AISI 316L 23 DN 100 PN 10 16 B1 AISI 316L ANSI flanges 30 1 1 2 150 Ibs RF AISI 316 316L 31 2 150 lbs RF AISI 316 316L 32 3 150 Ibs RF AISI 316 316L 33 4 150 lbs RF AISI 316 316L JIS flanges 7B 10K 40A RF AISI 316L 7C 10K 50A RF AISI 316L 7D 10K 80A RF AISI 316L 7L 10K 100A RF AISI 316L 40 Measuring range BA 0 to 100 mbar 1 mH2O...

Page 37: ...ousing Cable entry A0 Without housing e g for ordering spare parts G1 Polyester housing IP 66 gland M 20x1 5 G2 Aluminum housing IP 66 gland M 20x1 5 G3 AISI 316L housing IP 66 gland M 20x1 5 P2 Aluminum housing IP 66 plug M 12x1 P3 AISI 316L housing IP 66 plug M 12x1 T2 Aluminum housing IP 66 plug 7 8 T3 AISI 316L housing IP 66 plug 7 8 E1 Polyester housing NEMA 4X thread 1 2 NPT E2 Aluminum hous...

Page 38: ...16L EHEDG 3A 56 IDF 2 ISO 2853 AISI 316L EHEDG 3A 55 Varivent type N for pipes DN 40 DN 162 PN 40 AISI 316L EHEDG 44 DRD 65 mm PN 25 AISI 316L EHEDG 3A 00 Universal process adapter 44 mm incl silicone molded seal 3A 57 Universal process adapter 44 mm extension 6 incl silicone molded seal 3A 40 DIN 11851 DN 40 PN 40 AISI 316L 41 DIN 11851 DN 50 PN 40 AISI 316L 74 02 40 Measuring range BA 0 to 100 m...

Page 39: ...display 80 Housing Cable entry A0 Without housing e g for ordering spare parts G1 Polyester housing IP 66 gland M 20x1 5 G2 Aluminum housing IP 66 gland M 20x1 5 G3 AISI 316L housing IP 66 gland M 20x1 5 P2 Aluminum housing IP 66 plug M 12x1 P3 AISI 316L housing IP 66 plug M 12x1 T2 Aluminum housing IP 66 plug 7 8 T3 AISI 316L housing IP 66 plug 7 8 E1 Polyester housing NEMA 4X thread 1 2 NPT E2 A...

Page 40: ...16L 21 DN 50 PN 10 16 B1 AISI 316L 22 DN 80 PN 10 16 B1 AISI 316L 23 DN 100 PN 10 16 B1 AISI 316L ANSI flanges 30 1 1 2 150 Ibs RF AISI 316 316L 31 2 150 lbs RF AISI 316 316L 32 3 150 Ibs RF AISI 316 316L 33 4 150 lbs RF AISI 316 316L JIS flanges 7B 10K 40A RF AISI 316L 7C 10K 50A RF AISI 316L 7D 10K 80A RF AISI 316L 7L 10K 100A RF AISI 316L 40 Measuring range BA 0 to 100 mbar 1 mH2O 40 inH2O BB 0...

Page 41: ... g for ordering spare parts G1 Polyester housing IP 66 gland M 20x1 5 G2 Aluminum housing IP 66 gland M 20x1 5 G3 Stainless steel housing AISI 316L IP 66 gland M 20x1 5 P2 Aluminum housing IP 66 plug M 12x1 P3 Stainless steel housing AISI 316L IP 66 plug M 12x1 T2 Aluminum housing IP 66 plug M 7 8 T3 Stainless steel housing AISI 316L IP 66 plug 7 8 E1 Polyester housing NEMA 4X thread 1 2 NPT E2 Al...

Page 42: ...gth 0 5 to 100 m 30 Process connection Threaded connection 10 ISO 228 G 1 1 2 AISI 316L 11 ISO 228 G 1 1 2 Alloy C 12 ANSI 1 1 2 NPT AISI 316L EN flanges 20 DN 40 PN 10 16 B1 AISI 316L 21 DN 50 PN 10 16 B1 AISI 316L 22 DN 80 PN 10 16 B1 AISI 316L 23 DN 100 PN 10 16 B1 AISI 316L ANSI flanges 30 1 1 2 150 Ibs RF AISI 316 316L 31 2 150 lbs RF AISI 316 316L 32 3 150 Ibs RF AISI 316 316L 33 4 150 lbs R...

Page 43: ...housing e g for ordering spare parts G1 Polyester housing IP 66 gland M 20x1 5 G2 Aluminum housing IP 66 gland M 20x1 5 G3 Stainless steel housing AISI 316L IP 66 gland M 20x1 5 P2 Aluminum housing IP 66 plug M 12x1 P3 Stainless steel housing AISI 316L IP 66 plug M 12x1 T2 Aluminum housing IP 66 plug 7 8 T3 Stainless steel housing AISI 316L IP 66 plug 7 8 E1 Polyester housing NEMA 4X thread 1 2 NP...

Page 44: ...0 mbar 40 mH2O 1600 inH2O BE 0 to 10 bar 100 mH2O 4000 inH2O 50 Linearity Fill fluid 1 0 2 of measuring range FDA compliant 2 0 2 of measuring range inert oil 3 0 1 of measuring range FDA compliant 4 0 1 of measuring range inert oil Z Additional specification 60 Measuring sensor seal 1 Viton 2 EPDM 5 Kalrez 3 Sensor welded 70 Electronics Output Electronic inserts without integrated overvoltage pro...

Page 45: ... 12x1 P3 Stainless steel housing AISI 316L IP 66 plug M 12x1 T2 Aluminum housing IP 66 plug 7 8 T3 Stainless steel housing AISI 316L IP 66 plug 7 8 E1 Polyester housing NEMA 4X thread 1 2 NPT E2 Aluminum housing NEMA 4X thread 1 2 NPT E3 Stainless steel housing AISI 316L NEMA 4X thread 1 2 NPT F1 Polyester housing IP 66 thread G 1 2 A F2 Aluminum housing IP 66 thread G 1 2 A F3 Stainless steel hou...

Page 46: ...2 mH2O 480 inH2O GD 13 to 60 psi 40 mH2O 1600 inH2O GE 13 to 150 psi 100 mH2O 4000 inH2O 50 Linearity Fill fluid 1 0 2 of measuring range FDA compliant 2 0 2 of measuring range inert oil 3 0 1 of measuring range FDA compliant 4 0 1 of measuring range inert oil Z See additional specification 60 Measuring sensor seal 1 Viton 2 EPDM 5 Kalrez 3 Sensor welded 70 Electronics Output Electronic inserts wi...

Page 47: ...ter housing NEMA 4X thread 1 2 NPT E2 Aluminum housing NEMA 4X thread 1 2 NPT E3 AISI 316L housing NEMA 4X thread 1 2 NPT F1 Polyester housing IP 66 thread G 1 2 A F2 Aluminum housing IP 66 thread G 1 2 A F3 AISI 316L housing IP 66 thread G 1 2 A 90 Additional option 0 Basic version 5 200 inch connecting cable with housing adapter NEMA 6P separate electronics 7 inch connecting cable with housing a...

Page 48: ...mH2O 40 inH2O GB 6 to 6 psi 4 mH2O 160 inH2O GC 13 to 15 psi 12 mH2O 480 inH2O GD 13 to 60 psi 40 mH2O 1600 inH2O GE 13 to 150 psi 100 mH2O 4000 inH2O 74 02 50 Linearity Fill fluid 1 0 2 of measuring range FDA compliant 3 0 1 of measuring range FDA compliant 60 Measuring sensor seal 5 Kalrez 4 Viton only with universal process adapter 3 Sensor welded 70 Electronics Output Electronic inserts withou...

Page 49: ...housing IP 66 plug M12x1 P3 AISI 316L housing IP 66 plug M12x1 T2 Aluminum housing IP 66 plug 7 8 T3 AISI 316L housing IP 66 plug 7 8 90 Additional option 0 Basic version 5 200 inch connecting cable with housing adapter NEMA 6P separate electronics 7 inch connecting cable with housing adapter NEMA 6P separate electronics max 800 inch A Basic version adjusted measuring range D 200 inch connecting c...

Page 50: ...13 to 15 psi 12 mH2O 480 inH2O GD 13 to 60 psi 40 mH2O 1600 inH2O GE 13 to 150 psi 100 mH2O 4000 inH2O 50 Linearity Fill fluid 1 0 2 of measuring range FDA compliant 2 0 2 of measuring range inert oil 3 0 1 of measuring range FDA compliant 4 0 1 of measuring range inert oil Z Additional specification 60 Measuring sensor seal 1 Viton 2 EPDM 5 Kalrez 3 Sensor welded 70 Electronics Output Electronic ...

Page 51: ...lug M12x1 P3 AISI 316L housing IP 66 plug M12x1 T2 Aluminum housing IP 66 plug 7 8 T3 AISI 316L housing IP 66 plug 7 8 90 Additional option 0 Basic version 5 200 inch connecting cable with housing adapter NEMA 6P separate electronics 7 inch connecting cable with housing adapter NEMA 6P separate electronics max 800 inch A Basic version adjusted measuring range D 200 inch connecting cable with housi...

Page 52: ... FE 0 to 150 psi 100 mH2O 4000 inH2O GA 1 5 to 1 5 psi 1 mH2O 40 inH2O GB 6 to 6 psi 4 mH2O 160 inH2O GC 13 to 15 psi 12 mH2O 480 inH2O GD 13 to 60 psi 40 mH2O 1600 inH2O GE 13 to 150 psi 100 mH2O 4000 inH2O 50 Linearity Fill fluid 1 0 2 of measuring range FDA compliant 2 0 2 of measuring range inert oil 3 0 1 of measuring range FDA compliant 4 0 1 of measuring range inert oil Z Additional specifi...

Page 53: ...using IP 66 plug M12x1 P3 AISI 316L housing IP 66 plug M12x1 T2 Aluminum housing IP 66 plug 7 8 T3 AISI 316L housing IP 66 plug 7 8 90 Additional option 0 Basic version 5 200 inch connecting cable with housing adapter NEMA 6P separate electronics 7 inch connecting cable with housing adapter NEMA 6P separate electronics max 800 inch A Basic version adjusted measuring range D 200 inch connecting cab...

Page 54: ...O 480 inH2O FD 0 to 60 psi 40 mH2O 1600 inH2O FE 0 to 150 psi 100 mH2O 4000 inH2O 50 Linearity Fill fluid 1 0 2 of measuring range FDA compliant 2 0 2 of measuring range inert oil 3 0 1 of measuring range FDA compliant 4 0 1 of measuring range inert oil Z Additional specification 60 Measuring sensor seal 1 Viton 2 EPDM 5 Kalrez 3 Sensor welded 70 Electronics Output Electronic inserts without integ...

Page 55: ... housing NEMA 4X thread 1 2 NPT E2 Aluminum housing NEMA 4X thread 1 2 NPT E3 AISI 316L housing NEMA 4X thread 1 2 NPT P2 Aluminum housing IP 66 plug M12x1 P3 AISI 316L housing IP 66 plug M12x1 T2 Aluminum housing IP 66 plug 7 8 T3 AISI 316L housing IP 66 plug 7 8 90 Additional option 0 Basic version A Basic version adjusted measuring range DB53A Complete order code ...

Page 56: ...in confined or difficult to access mounting locations in the event of extreme fluctuations in temperature at the tank wall IP 68 protection applies for the housing adapter The mounting bracket is suitable for pipe and wall mounting See also page 19 Housing adapter with mounting bracket section and Page 31 Dimensions section Mounting bracket Mounting bracket for pipe and wall mounting Material AISI...

Page 57: ...es with a flat cover 942262 0000 Order number for protection cover for devices with a high cover 942262 0001 Welding flanges P01 DB5xxxxx 06 xx xx xx 032 Welding flange for flush mounted installation for devices with a DRD flange Note Order number for a replacement PTFE flat seal 916783 0000 1 1 0 137 155 ø125 ø50 ø66 ø105 45 3 13 16 15 20 4 x M10 4 x 90 360 ø84 Version Order number DRD DN 50 AISI...

Page 58: ...ers 52024469 and 52024470 Order number for pressure sensor dummy 52024471 Adapter You can use the following adapters to mount a DB50L with a universal process connection in a DRD dairy fitting or Clamp connection ø44 39 5 Rd 52 x 1 6 D Diameter D Material Order number 65 mm AISI 316L 214880 0002 65 mm AISI 316L with inspection certificate EN 10204 3 1 material 52010174 85 mm AISI 316L 52006262 85 ...

Page 59: ...e Electronics Documentation ATEX II 1 2 G EEx ia IIC T6 DB50 DB50L DB51 DB52 PFM 4 to 20 mA HART PROFIBUS PA FOUNDATION Fieldbus XA002F XA002F XA007F XA135F ATEX II 2 G EEx ia IIC T6 DB53 PFM 4 to 20 mA HART PROFIBUS PA FOUNDATION Fieldbus XA002F XA002F XA007F XA135F ATEX 1 2 G EEx nA II T6 DB50 DB50L DB51 DB52 DB53 PFM 4 to 20 mA HART PROFIBUS PA FOUNDATION Fieldbus XA189F XA189F XA189F XA189F AT...

Page 60: ...service Ersatzteile Reparatur Kalibrierung Tel 0800 EHSERVICE Tel 0800 3 47 37 84 service de endress com Technische Büros Hamburg Hannover Ratingen Frankfurt Stuttgart München Berlin Endress Hauser Ges m b H Lehnergasse 4 1230 Wien Tel 43 1 88 05 60 Fax 43 1 88 05 63 35 info at endress com www at endress com Endress Hauser Metso AG Sternenhofstraße 21 4153 Reinach BL 1 Tel 41 61 7 15 75 75 Fax 41 ...