Endress+Hauser Analytik Jena Biometra TOne Short Manual Download Page 2

Quick Reference Guide EN 02_19 

Biometra TOne 

 

Press [

Tools

] to access the system settings, user management, documentation, 

backup tool or self-test functions. 

 

Press 

[Logout

] to log out. 

 

Press [

Programs

] on the TOne home screen The program overview screen opens: 

 

 

To edit a template, press [

New from template

], select a template from the list and 

press [

Open template

]. 

 

To edit a program, select a user directory and a program and then press [

Edit

]. 

 

Alternatively, a user or a program can be selected via the quick selection 

.

 

The TOne programming screen opens. Use the following buttons to toggle between 
the different programming modes: 

Graphical mode 

 

Spreadsheet mode 

 

Gradient mode 

 

Spreadsheet programming screen 

Graphical programming screen 

 

 

 

Enter a program name. To do this, touch the "

Name

" input field and enter a name 

using the TOne keyboard. 

 

Define the status and the temperature of the heated lid. Touch the "

Heated lid

input field and switch the heated lid on or off. If the heated lid is switched on, enter 
a temperature between 30°C and 110°C. 

 

To switch the heated lid preheating on or off, press the corresponding button. 

 

Select a program step and press [

Edit

]. The screen for editing program steps opens: 

 

Editing, saving and copy-
ing programs 

Summary of Contents for Analytik Jena Biometra TOne

Page 1: ...TICE The use of oil between samples and sample block is not necessary If you wish to use oil never use silicone oil Use mineral oil Ensure that the ventilation slits are clear Important Release the lid wheel before opening the lid Adjust the lid wheel for every individual run After the TOne has completed the initial self test the login screen is displayed Press Login to log in as an existing user ...

Page 2: ...One programming screen opens Use the following buttons to toggle between the different programming modes Graphical mode Spreadsheet mode Gradient mode Spreadsheet programming screen Graphical programming screen Enter a program name To do this touch the Name input field and enter a name using the TOne keyboard Define the status and the temperature of the heated lid Touch the Heated lid input field ...

Page 3: ...dient programming Lin For standard programming enter a temperature for both the first and last row in the sample block For linear programming enter the primer annealing tem perature and set a temperature increment The gradient curve is displayed graph ically Press to confirm your entries Press on the screen for editing program steps to accept the settings The soft ware leaves the screen and opens ...

Page 4: ... each user To quick start a program press the Quick Start button on the TOne home screen Se lect a program from the list and press Start To start a program from a user directory press Programs on the TOne home screen On the next screen select a directory and a program and press Start After the start the current program is shown in a spreadsheet graphical or gradi ent view Use the same buttons as i...