Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference.
Warning
This is a Class 1 product and must be earthed
Please read these instructions carefully before
commencing any work.
This unit must be fitted by a competent and qualified
electrician.
Install in accordance with IEE Wiring regulations and
current Building Regulations.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting. Ensure other
persons cannot restore the electrical supply without your
knowledge.
This light fitting should be connected to a fused circuit.
If replacing an existing fitting, make a careful note of the
connections.
This product is not suitable for dimming.
This product is rated at IP44.
This fitting is heavy and you will require assistance
in connecting it to the supply and securing it to the
mounting surface.
Be careful during handling and maintenance to avoid
breakage of the glass parts.
Specification
Voltage:
240V 50Hz a.c.
Lamp:
2 x 15W G13 T8
IP rating:
44
Layout
• Plan the desired layout of this fitting carefully, ensuring
the cables will reach the distance between the junction
box and the light fitting.
• Avoid locating any cables in positions that would cause
a hazard. Position cables and junction boxes (not
supplied) away from areas where they may be at risk
from being cut, trapped or damaged. Ensure there are
no pipes or cables beneath the mounting surface.
• Cables in walls must be protected using suitable
conduit or plastic trunking.
• The mains supply cable must have a minimum cross
sectional area of 1.0mm².
• This product has special protection against the ingress
of moisture and is IP44 rated.
Existing fittings must be completely removed before
installation of a new product. Before removing the existing
fitting,
carefully note the position of each set of wires
.
• Diagram 1: Make sure that the shelves / brackets are
kept in a safe position until required. Remove the mirror
side panels by removing the 4 side screw assemblies
(A), retain these for re-use. Carefully take out the two
fluorescent tubes.
• Unpack the door, and affix to the hinges using the 8
short screws and washers.
• Diagram 2: Mark out the 4 mounting positions as
shown, and determine the position of the cable
entry. Drill and plug the mounting surface. Bring the
mains cable through the rubber grommet in the back
housing and secure the back housing to the mounting
surface – making sure that the sides are vertical and
the top is horizontal.
NOTE: The rubber grommet
must be used at the cable entry point to ensure
that the water ingress protection of the fitting is
maintained.
• Wire as below.
Installation
Having correctly identified the wiring from your existing light
fitting, pull the wire through the hole and connect to the
connection block inside the product in the following way:
Wiring
Check that...
• You have correctly identified the wires
• The connections are tight
• No loose strands have been left out of the connection
block.
This product is suitable for use in Zones 1, 2 and outside
Zones of a bathroom. See diagram. If this unit is being fitted
in a room containing a bath or shower, a 30mA RCD must
be used, in accordance with IEE regulations.
Please see the latest version of BS 7671: “Requirements
for Electrical Installations” for more information.
SUPPLY
NEUTRAL
LIGHT FITTING
BLUE (N)
EARTH (GREEN/YELLOW)
GREEN/YELLOW
BROWN (L)
SWITCHED LIVE
OUTSIDE ZONES
ZONE
2
ZONE
1
0.6m
0.6m
2.25m
Ceiling
Diagram 1
(A)
(A)
Diagram 2
Shaver
socket
Diagram 3
1-3mm
2.5-3mm