background image

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory 
operation of this product. Please retain these instructions for future reference.

Warning

This is a Class 1 product and must be earthed

Please read these instructions carefully before 
commencing any work. 

This unit must be fitted by a competent and qualified 
electrician.

Install in accordance with IEE Wiring regulations and 
current Building Regulations.

To prevent electrocution switch off at mains supply 
before installing or maintaining this fitting. Ensure other 
persons cannot  restore the electrical supply without your 
knowledge.

This light fitting should be connected to a fused circuit.

If replacing an existing fitting, make a careful note of the 
connections.

This product is not suitable for dimming.

This product is rated at IP44.

This fitting is heavy and you will require assistance 
in connecting it to the supply and securing it to the 
mounting surface.

Be careful during handling and maintenance to avoid 
breakage of the glass parts.

Specification

Voltage: 

240V 50Hz a.c.

Lamp: 

2 x 15W G13 T8

IP rating: 

44

Layout

•  Plan the desired layout of this fitting carefully, ensuring 

the cables will reach the distance between the junction 
box and the light fitting.

•  Avoid locating any cables in positions that would cause 

a hazard. Position cables and junction boxes (not 
supplied) away from areas where they may be at risk 
from being cut, trapped or damaged. Ensure there are 

no pipes or cables beneath the mounting surface.

•  Cables in walls must be protected using suitable 

conduit or plastic trunking.

•  The mains supply cable must have a minimum cross 

sectional area of 1.0mm².

•  This product has special protection against the ingress 

of moisture and is IP44 rated.

Existing fittings must be completely removed before 
installation of a new product. Before removing the existing 
fitting, 

carefully note the position of each set of wires

.

•  Diagram 1: Make sure that the shelves / brackets are 

kept in a safe position until required. Remove the mirror 
side panels by removing the 4 side screw assemblies 
(A), retain these for re-use. Carefully take out the two 
fluorescent tubes.

•  Unpack the door, and affix to the hinges using the 8 

short screws and washers.

•  Diagram 2: Mark out the 4 mounting positions as 

shown, and determine the position of the cable 
entry. Drill and plug the mounting surface. Bring the 
mains cable through the rubber grommet in the back 
housing and secure the back housing to the mounting 
surface – making sure that the sides are vertical and 
the top is horizontal. 

NOTE: The rubber grommet 

must be used at the cable entry point to ensure 
that the water ingress protection of the fitting is 
maintained.

•  Wire as below.

Installation

Having correctly identified the wiring from your existing light 
fitting, pull the wire through the hole and connect to the 
connection block inside the product in the following way:

Wiring

Check that...

•  You have correctly identified the wires
•  The connections are tight
•  No loose strands have been left out of the connection 

block.

This product is suitable for use in Zones 1, 2 and outside 
Zones of a bathroom. See diagram. If this unit is being fitted 
in a room containing a bath or shower, a 30mA RCD must 
be used, in accordance with IEE regulations.

Please see the latest version of BS 7671: “Requirements 
for Electrical Installations” for more information.

SUPPLY

NEUTRAL

LIGHT FITTING

BLUE (N)

EARTH (GREEN/YELLOW)

GREEN/YELLOW

BROWN (L)

SWITCHED LIVE

OUTSIDE ZONES

ZONE

2

ZONE

1

0.6m

0.6m

2.25m

Ceiling

 

Diagram 1

(A)

(A)

Diagram 2

Shaver 

socket

Diagram 3

1-3mm

2.5-3mm

Reviews: