76546_76548-Burford-WB 20180626
Endon Lighting, LS9 0SE
Burford Outdoor Wall light Fitting
Safety Warnings
INSTRUCTION MANUAL
•
This product is only suitable for connection to a 240V~50Hz supply in accordance with current IEE wiring
regulations. It should be installed in accordance with local building regulations and is for domestic use only.
• Before commencing installation of your light fitting always switch off the mains supply and remove the appropriate
fuse or switch off the appropriate circuit breaker.
• This is a Class I product, and must be Earthed.
The terminal blocks are supplied according to requirements of
the fitting.
•
Run supply wire from a 5-amp electrical supply protected by an RCD using double insulated 3-core cable of type
H05RN-F 1.0mm2 (not supplied) to selected site, ensuring it is adequately protected through the full length of the
cable run, it must come out of the flat surface of the wall or steps in line with the entry to the fitting.
• Except where installed in a conduit or duct which provides equivalent protection against mechanical damage,
a cable buried in the ground shall incorporate an earthed armour or metal sheath or both, suitable for use as a
protective conductor, or be of insulated concentric construction. Buried cables shall be marked by cable covers or
a suitable marking tape. Buried conduits and ducts shall be suitably identified. Buried cables, conduits and ducts
shall be at a sufficient depth to avoid being damaged by any reasonably foreseeable disturbance of the ground.
• Never fit bulbs of a higher wattage than those specified on the label, as these may cause overheating and damage
the fitting.
•
This product has special protection against the ingress of water, and is rated IP44.
• If any modification is made it will invalidate the warranty and may render the product unsafe.
Assembly/ User Instructions
Before you start
Please read these instructions carefully before fitting and retain for reference. Check the packaging and make sure
that you have all the required parts. Follow each assembly step in order to prevent incorrect assembly. Ensure that
the product is fully assembled as illustrated before use.
The Light pack contains:
Light fitting.
Terminal connection block(s).
Fixing pack.
The following tools may be required:
Selection of cross and flat head screwdrivers.
Electric drill and assorted drill bits.
Wire strippers.
Electrical insulation tape.
Care Information
Allow 10 minutes to cool before replacing, adjusting or cleaning.
Clean with a dry cloth only. Do not use liquid or abrasive cleaners on this product.
These assembly diagrams are intended as a guide – if in doubt consult a qualified electrician.
1.
Decide on the position of the light fitting, or remove existing light fitting. Note the position of the electrical
connections. Ensure there is a solid mounting surface.
2.
Remove the finials (A) from the front of the product and lift the light fitting body away from the wall back (B). Keep
the finials in a safe place for refitting later.
3.
Using the wall back (B) as a template, mark the position of the mounting holes. Drill holes, taking care to avoid
damaging any concealed wiring or pipes. Make sure the wall back is correctly oriented with the drain hole at the
base
4.
Bring the mains cable through the rubber grommet, then use appropriate fixings (C & D) to secure the wall back
to the wall.
5. Connect the house wiring to the internal terminal block (E) – see expanded wiring details below.
NOTE: This is a
Class I fitting and must be earthed.
The cable entry grommet must be securely in place to ensure that the water
ingress protection is maintained. When you are sure of the connections wrap the Terminal
Block and overlap the wiring both sides with 2 layers of insulation tape.