Endon Burford Outdoor Post Light Instruction Manual Download Page 2

76549-Burford-Post 20181127

Endon Lighting, LS9 0SE

1.  Determine the position of your light fitting taking into account the entry position of the cable and make sure 

there is sufficient cable coming out of the floor to connect to the terminal block. Ensure that the mounting 

surface is solid, preferably a brick or block floor and ensure that there are no other cables or pipes beneath 

the surface. 

2.  Diagram 

A

: Connect the house wiring to the terminal block (Fig 2.). Remove the terminal bracket from the 

base. Remove the terminal block box lid. Connect the mains supply. Replace terminal block box lid. Replace 

terminal bracket onto base. 

NOTE: This is a Class I fitting and must be earthed. 

Check the seal, use 

sealant if required.

3.  Diagram 

B

. Use appropriate fixings to secure the post to the mounting surface (1&2)

4.   Fit the glass pieces into their slots in the frame (3).
5.  Fit the bulb (not supplied) into the lamp holder (4). 

NOTE: Never fit a bulb of a higher wattage than that 

specified on the label (as this may cause overheating and damage the fitting).

 

6.  Attach the lid of the fitting with the hex nuts (5), ensuring a good seal to maintain ingress protection.
7.  Turn on the power and test.

Assembly/ User Instructions Continued

Diagram A

Diagram B

4

5

3

Reviews: