ENDEAVOUR TOOLS
ET8626_User Manual
8
ET8626
Rating range as following:
Measure Standard
Measure Range
CCA
100-2000
BCI
100-2000
CA
100-2000
MCA
100-2000
JIS
26A17--245H52
DIN
100-1400
IEC
100-1400
EN
100-2000
SAE
100-2000
GB
100-1400
Input correct test standard and rating, press ENTER key, tester starts to test, and dynamic interface "TESTING" prompted. See below:
It takes around 3 seconds to display the battery test result.
Battery Test Result
Battery test result includes 5 types as following:
1) Good Battery
The battery is without any problem, please be relaxed to use!
2) Good, Recharge
Good battery but low current, recharge before using.
500
CCA
Setting Rate
Healthy:96% 490CCA
Charge:98% 12.64V
Internal R=6.1m
Ω
Rated: 500A
GOOD BATTERY
Healthy:78% 440CCA
Charge:30% 12.20V
Internal R=7.2m
Ω
Rated: 500A
GOOD, RECHARGE