background image

The lower limit
of the setpoint.
Adjustable between
0.01 and 

T.uPl.

The upper limit
of the setpoint.
Adjustable between

T.lol

 

and 99.59.

Selection of start type.
By external start input and 
start/stop keys, timer can be run 
and stopped. 4 different selection 
types are defined in the 
control diagram.
Selection of relay output.
If 

typ.0

 is selected, timer runs 

by start and relay contact  shuts.
When time is over, relay contact 
opens. If 

typ.1

 is selected, timer 

runs by start. When time is over, 
relay contact shuts.

Selection of buzzer sound.
Adjustable 16 different sounds.
If this parameter is selected 0, 
warning tone is canceled.

Selection of time unit.
If 

min

 is selected, time can be 

adjutable max. 99:59 min. 
If 

Hour

 is selected, time can be 

adjutable max. 99:59 h. 

Increase or decrease 
step of the setpoint.
Adjustable between
1 and 30.

When pressed       key, TIMER set value flashes and by using       and      keys the value can be adjusted 

with the step defined by

In.de

.

Programming Mode

Run Mode

Time 
value

T.lol

T.uPl

Str.t.

Str.t.

Str.t.

In.de

Out.t.

Sond.

Out.t.

Out.t.

TYP.0

TYP.1

TYP.2

TYP.3

1000

 ETM

1

411-E-0

5-R

If        key is pressed and held for 3 seconds,
programming mode is entered.

:

30 59

:

60 00

:

59 59

:

60 00

SET

T.bas

S.Cod.

Access code for entering 
security menu.
This parameter should be 411.

Access code for 
timer configuration menu.

A.-t.S.

A.-T.c.

Access code for timer set menu

If         key is pressed,
run mode is entered.

T.S.

T.c.

SE

Used for adjusting the value of the setpoint in the run mode and for adjusting the selected parameter in the programming mode.  For adjusting the selected parameter, while holding        key, the value can be 
adjusted by using        and        keys. 

 

When held down for one second in the run mode, timer runs. 
run mode. When held down for a few seconds, the change rate accelerates. 

 

Used for selecting menu and increasing setpoint value of the parameters in the programming mode and for increasing the setpoint value in the 

When held down for one second in the run mode, timer and voiced warning are stopped.(When 

Str.t.

 = 

TYP.1

 mode is selected, timer and voiced warning can be stopped if external start input is off). Used 

for selecting parameters and decreasing the setpoint value in the programming mode and for decreasing the setpoint value in the run mode. When held down for a few seconds, the change rate accelerates.

INDICATOR OF 
SELECTING 
HOUR

INDICATOR OF 
SELECTING 
MINUTE

INDICATOR OF
CONTACT OUTPUT

Displayed time value in the run mode, parameter value or name in the programming mode.

2/2

Power

Power

Power

Power

Out

Out

Out

Out

Start
input

Start
key

Start
input

Start
key

Stop
key

Stop
key

Stop
key

Indicator

Indicator

Indicator

Indicator

CONTROL DIAGRAM BY EXTERNAL START INPUT

CONTROL DIAGRAM BY START & STOP KEYS

NonE

= Menu is invisible.

P.yes

= Parameters of menu 

               are changeable.

P.no

= Parameters of menu 

            are only visible.

NonE

= Menu is invisible.

P.yes

= Parameters of menu 

               are changeable.

P.no

= Parameters of menu 

            are only visible.

TYP.0

TYP.0

TYP.0

TYP.1

TYP.1

SET

SET

 ETM1411

ENDA

 

DIGITAL TIMER

 STOP

 START

 OUT  

 MIN  

 HOUR

Reviews: