The lower limit
of the setpoint.
Adjustable between
0.01 and
T.uPl.
The upper limit
of the setpoint.
and 99.59.
Adjustable between
T.lol
Selection of start type.
By external start input and
start/stop keys, timer can be run
and stopped. 4 different selection
types are defined in the
control diagram.
Selection of relay output.
If
is selected, timer runs
by start and relay contact shuts.
When time is over, relay contact
opens. If
is selected, timer
runs by start.
typ.0
typ.1
When time is over,
relay contact shuts.
Selection of buzzer sound.
Adjustable 16 different sounds.
If this parameter is selected 0,
warning tone is canceled.
Selection of time unit.
If
is selected, time can be
adjutable max. 99:59 min.
If
is selected
min
Hour
, time can be
adjutable max. 99:59 h.
Increase or decrease
step of the setpoint.
Adjustable between
1 and 30.
When pressed key, TIMER set value flashes and by using and keys the value can be adjusted
with the step defined by
In.de
.
Programming Mode
Run Mode
Time
value
T.lol
T.uPl
Str.t.
Str.t.
Str.t.
In.de
Out.t.
Sond.
Out.t.
Out.t.
TYP.0
TYP.1
TYP.2
TYP.3
1000
2./2
ETM1411-E
SET
SET
SET
SET
If key is pressed and held for 3 seconds,
programming mode is entered.
30 59
:
60 00
:
59 59
:
60 00
:
SET
T.bas
S.Cod.
Access code for entering
security menu.
This parameter should be 411.
Access code for
timer configuration menu.
A. t.S.
-
A. T.c
-
.
Access code for timer set menu
If key is pressed,
run mode is entered.
T.S.
T.c.
SE
Used for adjusting the value of the setpoint in the run mode and for adjusting the selected parameter in the programming mode. For adjusting the selected parameter, while holding key, the value can be
adjusted by using and keys.
When held down for one second in the run mode, timer runs. Used for selecting menu and increasing setpoint value of the parameters in the programming mode and for increasing the setpoint value in the
run mode. When held down for a few seconds, the change rate accelerates.
When held down for one second in the run mode, timer and voiced warning are stopped.(When
=
mode is selected, timer and voiced warning can be stopped if external start input is off). Used
for selecting parameters and decreasing the setpoint value in the programming mode and for decreasing the setpoint value in the run mode. When held down for a few seconds, the change rate accelerates.
Str.t. TYP.1
INDICATOR OF
SELECTING
HOUR
INDICATOR OF
SELECTING
MINUTE
INDICATOR OF
CONTACT OUTPUT
Displayed time value in the run mode, parameter value or name in the programming mode.
SET
SET
START
STOP
DIGITAL TIMER
ENDA
ETM1411
OUT
MIN
HOUR
Power
Power
Power
Power
Out
Out
Out
Out
Start
input
Start
key
Start
input
Start
key
Stop
key
Stop
key
Stop
key
Indicator
Indicator
Indicator
Indicator
CONTROL DIAGRAM BY EXTERNAL START INPUT
CONTROL DIAGRAM BY START & STOP KEYS
NonE
P.yes
P.no
= Menu is invisible.
= Parameters of menu
are changeable.
= Parameters of menu
are only visible.
NonE
P.yes
P.no
= Menu is invisible.
= Parameters of menu
are changeable.
= Parameters of menu
are only visible.
TYP.0
TYP.0
TYP.0
TYP.1
TYP.1