SET
SET
SET
&
SET
S.Cod.
Uo.sc.
D.Ca.s.
d.Pnt.
=
Decimal point can be adjusted between
1. and 3. digits.
See NOTE 1 for programming.
Decimal point.
s.Cod.
= Access code for safety menu.
This parameter should be
222.
See NOTE 1 for programming.
s.Cod.
= Access code for safety menu.
This parameter should be
333.
See NOTE 1 for programming.
Uo.Sc.
=
U.oPt.
parameter.
nonE
= No menu is seen.
P. no
= Menu is seen but can not be programmed.
P.yES
.
= Menu is seen and programming is possible.
See NOTE 1 for programming.
menu protection level
d.Ca.S.
=
d.CAL.
parameter.
nonE
= No menu is seen.
P. no
= Menu is seen but can not be programmed.
P.yES
.
= Menu is seen and programming is possible.
See NOTE 1 for programming.
menu protection level
L.SCL.
= Lower value of the scale.
It can be adjusted between -1999 and (
H.SCL.
-100)
Output becomes 0,1mA at the adjusted value.
See NOTE 1 for programming.
Lo.Li.
= Lower limit for preset value.
It can be adjusted between
l.SCL.
and
See NOTE 1 for programming.
Hi.Li.
H.SCL.
= Upper value of the scale
It can be adjusted between (
L.SCL.
+100) and 8000.
Output becomes 20mA at the adjusted value.
See NOTE 1 for programming.
Hý.Lý.
= Upper limit for preset value.
It can be adjusted between
Lo.li.
and
H.SCl.
See NOTE 1 for programming.
S.Cod.
10CA/
First press and hold key. Then, by using keys, preset value can be adjusted.
d.Cal.
SeCU.
D.Pnt.
l.sCl.
Lo.LI.
H.sCl.
HI.LI.
U.oPt.
10.CA.
= calibration for 0-20mA output.
The device should be calibrated until
20.00mA is obtained at the output.
Calibration procedure is as explained below.
When key is pressed, previous calibration
value is seen. While holding key, calibration
value should be adjusted until 20.00mA is seen
at the output by using keys .
If key is released, calibration is exited. In the
mean time, the new calibration value is saved
in an EEPROM.
Programming mode
3/3
Run mode
Preset
value
1000
1000
1001
1002
1001
EDP741C-E-03-R
For adjusting a selected parameter first press and hold key. Then, by using keys, adjustment can be made.
Parameter adjustment method
NOTE 1
If increment key is pressed and held 0.6 seconds, the value of the selected parameter changes rapidly. If waited enough, th eValue increases
100 at each step. After 1 second following the release of the key, initial condition is returned. The same procedure is valid for the decrement key.
If first and then keys are pressed together.
programming mode is entered.
If
o.E.t.Y
and
o.d.t.Y
parameters is adjusted to any value except
dSAb
parameter,
output can be controlled with and buttons.
D.o.sc.
d.o.Sc.
=
d.oPt.
parameter.
nonE
= No menu is seen.
P. no
= Menu is seen but can not be programmed.
P.yES
.
= Menu is seen and programming is possible.
See NOTE 1 for programming.
Menu protection level
P.on.C.
o.e.ty.
R.ti.
o.d.ty.
D.tI.
D.oPt.
P.on.C.
= Control parameter when first energized
ofF
= When first energized, output is the current
that lower limit value is indicated.
Attention: If this parameter is selected,
the set value that was adjusted before is seen
when set button is pressed at first. In addition,
if increasing or decreasing that value is wanted
the set value is equalized to lower limit value and
then adjustment can be done.
on
= When first energized, output is the current
that the set value is indicated.
S.Str.
= When first energized, output is increased
slowly from the current that lower limit value
is indicated to the current that set value is indicated
during
r.ti
.
See NOTE 1 for programming.
.
D.ti.
= decreasing time for output.
It is adjusted between 1 and 250 seconds.
Output current is decreased slowly to the lower limit value during
adjusted time.
See NOTE 1 for programming.
P.on.C.
o.d.ty.
o.E.ty.
Lo.lý.
Lo.lý.
off
Dsab.
Dsab.
on
Enb.
R.ti.
R.ti.
Enb.
S.str.
S.off.
S.on.
PRESET
PRESET
Control isn’t done
with buttons.
by pressing
the button
0
,1mA
Power
O
u
t
O
u
t
On
D.ti.
o.e.ty.
= Adjusted type of the output to
with button.
dSAb.
= Output cannot be adjusted to preset value with
button.
Enb.
= Output can be adjusted to preset value with
button.
S.on.
= Output is increased to voltage that set value is
displayed with button during
r.ti.
.
See NOTE 1 for programming.
preset value
o.d.ty.
= Adjusted type of the output to lower limit value
with button.
dSAb.
= Output cannot be adjusted to lower limit value with
button.
Enb.
= Output can be adjuested to lower limit value with
button.
S.oFF.
= Output is increased to voltage that lower limit
value is displayed with button during
d.ti.
.
See NOTE 1 for programming.
R.ti.
= increasing time for output.
It is adjusted between 1 and 250 seconds.
Output current is incerased slowly to the set value during adjusted time.
See NOTE 1 for programming.
by pressing
the button
by pressing
the button
by pressing
the button
P.I.d.t.
P.i/d/t/
= increasing and decreasing speed of preset value.
It is adjusted between 1 and 3.
P.i.d.t.
= 1, set value changes
one by one.
P.i.d.t.
= 2, set value changes 10 at each step.
P.i.d.t.
= 3, set value changes 100 at each step.
See NOTE 1 for programming.
&
SET
SET
SET
&
SET
SET
SET
.