4 digits 7 segment yellow LED display
( 2 ),( 3 ),( 4 ) Keypad
( 1 ) Digital display
2/3
EDP141
-E-05
2
1
184-253V AC
50/60Hz 3VA
230V AC
Besleme
Anahtar
Fuse
F 100 mA 250V AC
9.1mm
Micro switch
Note 1) Panel thickness should
be maximum 7mm
2) If there is no 60mm free
space at back side of the
device, it would be difficult
to remove it from the panel.
3
4
m
m
70mm
8mm
85mm
71mm
2
9
m
m
Flush mounting
clamp
Rubber
Panel
2
1
SN
: X
XX
XX
XX
XX
1
2
3
4
5
6
7
8
9
10
11
12
EN
DA
IN
DU
ST
RIA
L E
LE
CT
RO
NIC
S
2
3
0
V
A
C
+
1
0
%
-
2
0
%
5
0
/6
0
H
z
3
V
A
EI141
SET
ENDA
EDP141
DIGITAL POTENTIOMETER
E
DP
14
1 D
IG
IT
AL
P
OT
EN
TIO
ME
TE
R
0
-1
0
V
D
C
O
U
P
U
T
G
N
D
SN: XXXXXXXXX
1
2
3
4
5
6
7
8
9 10 11 12
EDP141 DIGITAL POTENTIOMETER
ENDA
INDUSTRIAL ELECTRONICS
2
3
0
V
A
C
+
1
0
%
-
2
0
%
5
0
/6
0
H
z
7
V
A
0
-1
0
V
D
C
O
U
P
U
T
G
N
D
SN: XXXXXXXXX
1
2
3
4
5
6
7
8
9 10 11 12
ENDA
INDUSTRIAL ELECTRONICS
2
4
V
D
C
1
0
%
7
V
A
±
G
N
D
EDP141-24DC DIGITAL POTENTIOMETER
-
+
SN: XXXXXXXXX
1
2
3
4
5
6
7
8
9 10 11 12
EI141-24AC DIGITAL POTENTIOMETER
ENDA
INDUSTRIAL ELECTRONICS
2
4
V
A
C
+
1
0
%
-
2
0
%
5
0
/6
0
H
z
7
V
A
G
N
D
0
-1
0
V
D
C
O
U
P
U
T
0
-1
0
V
D
C
O
U
P
U
T
1) Adjusted potentiometer value is seen in run mode
Parameter name, value or its unit in programming mode.
3) Decrement key during run mode.
Decrement or parameter selection key during programming mode.
2) Increment key during run mode.
Increment or parameter selection key during programming mode.
4) Used for selecting run or programming modes and for adjusting parameters.
-
Push up the flush-mounting
clamp in direction
1
as
shown in the figure above.
-
Then, pull out the clamp in
direction
2.
For removing mounting clamps:
DIMENSIONS
Panel cut-out
Flush mounting
clamp
TERMS
ENDA EDP 141 is intended for installation in control panels. Make sure that the device is used only for intended purpose.
During an installation, all of the cables that are connected to the device must be free of energy. The device
must be protected against inadmissible humidity, vibrations, severe soiling and make sure that the operation temperature is not exceeded. All
input and output lines that are not connected to the supply network must be laid out as shielded and twisted cables. These cables should not be
close to the power cables or components.
The shielding must be
grounded on the instrument side.
The installation and electrical connections must be carried on by a qualified staff and must be
according to the relevant locally applicable regulations.
CONNECTION DIAGRAM
Neutral
Line
SUPPLY :
NOTE :
Fuse should
be connected
Cable size: 1,5mm²
Holding screw
0.4-0.5Nm
Equipment is protected throughout
by DOUBLE INSULATION.
Note: 1) Mains supply cords shall meet the requirements of IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the power supply switch shall bring the identification of the relevant instrument and it
should
be easily accessible by the operator.
Character height
EI141
SET
ENDA
EDP141
DIGITAL POTENTIOMETER