Encyclon SELF-PRIME Installation, Operation And Troubleshooting Download Page 2

Liquid pressure out of the cyclone should be 0- 10 P.S.I.

E.

The swarf container should be emptied from time to time by pouring of the 
liquid and depositing the swarf material in a suitable waste collector.

3.

TROUBLESHOOTING

A.

Low "Cyclone In", pressure below 25 P.S.I.

1.

Disassemble and check for obstructions in suction line from sump 
to pump.

2.

Disassemble and check for obstruction in pump casing and 
impeller.

B.

High "Cyclone Out" pressure above 10 P.S.I.

1.

Check for restriction in return line to sump.

2.

Check for clogged cyclones.

C.

Clogging of ceramic nozzles.

1.

In a rare case of clogged nozzles, Stop pump motor and remove cap   

                                    nut to inspect inside of ceramic nozzle.  If clogged, a 1/8 inch wire         
                                    may be used to free up and clear material from cyclone.  After               
                                    cleaning replace nozzle and cap nut.

            2.        Check input strainer, perforations should be sized less than 1/8”            

                                   diameter to avoid clogging 1/4” hole in the end of the cyclone cone. 

                        3.         Run the system long enough to clear debris from           

 

                                    input lines before shut down (1 to 2 minutes)