background image

E9 IN REV. A   

1

   

 
 

 

 

 

E9 

 

PROFESSIONAL 2-WAY LCD REMOTE CAR STARTER & 6 CHANNEL 

ALARM SYSTEM 

With  

Built-in Voltage & Temperature Sensor 

And Two Way Serial Port Data Link

 

 

 

 

INSTALLATION MANUAL

 

 

 
 
 

This unit is designed for professional installation only and must be installed by an 

Encore authorized dealer.    Please register this product at 

www.encoreautomotivesystems.com

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for E9

Page 1: ... SYSTEM With Built in Voltage Temperature Sensor And Two Way Serial Port Data Link INSTALLATION MANUAL This unit is designed for professional installation only and must be installed by an Encore authorized dealer Please register this product at www encoreautomotivesystems com ...

Page 2: ... Do not use conventional crimp lock bullet on any wiring Poor wiring i e taped joints will possibly introduce unreliability into the alarm system and may result in false alarms or incorrect operation We suggest soldering all connection points Install the wiring neatly under carpets or behind trim to prevent possible damage to wires FOR AUTHORIZED DEALER TECHNICAL SUPPORT PLEASE CALL Toll Free 855 ...

Page 3: ...E9 IN REV A 3 6 PIN HEAVY GAUGE WIRE HARNESS ...

Page 4: ...t Yellow Ignition 1 Output Brown Acc Heater Output 5 PIN WIRE HARNESS Red 12v Battery Power Brown Siren Output Black System Main Ground White Parking Light Relay Output Red White Parking Light Relay Power Input 3 PIN DOOR LOCK CONNECTOR 1 Blue Wire 3 Green Wire Lock Pulse Unlock Pulse Unlock Pulse Lock Pulse WIRING ...

Page 5: ...current start solenoid wire of the ignition switch harness This wire has 12 volts when the ignition switch is turned to the START CRANK position only This wire has 0 volts in all other ignition switch positions NOTE This wire must be connected to the vehicle side of the starter cut relay when used For the electrical neutral switch configuration this connection must be made between the starter inhi...

Page 6: ... dashboard on top of the shifter console or on the dashboard face Leave at least 6mm space behind the mounting location for LED housing Once a suitable location is chosen drill a 6mm hole Run the LED wires through the hole then press the 2 pin LED housing into place Route the LED wires to the control module 5 PIN WIRE HARNESS RED WHITE WIRE PARKING LIGHT RELAY INPUT The RED WHITE wire is the input...

Page 7: ...as far as possible 2 PIN BLUE CONNECTOR FOR THE VALET SWITCH Select a mounting location for the switch that is easily accessible to the driver of the vehicle The switch does not have to be concealed however concealing the switch is always recommended as this provides an even higher level of security to the vehicle Mount the valet switch in a hidden but accessible location Route the valet switch wi...

Page 8: ...are the ignition coil itself the back of the gauges engine computers and automatic transmission computers IMPORTANT Do not test tachometer wires with a test light or logic probe The vehicle will be damaged How to find a tachometer wire with your multi meter 1 Set the ACV or AC voltage 12V or 20V is fine 2 Attach the probe of the meter to chassis ground 3 Start and run the vehicle 4 Probe the wire ...

Page 9: ...the built in timer to send a ground signal for any time interval between 1 second and 2 minutes For instance this timer output may be used to turn on the headlight with the remote control Also on certain BMW Mercedes Benz Jaguar and Volkswagen cars you can use this unique timed output to allow remote closure of all power window and sunroof without the need for an external module Blue wire Ground I...

Page 10: ...m is armed The current capacity of this wire is 200mA This output can control starter disable when an intrusion is detected and the system is triggered The vehicles prevent from any unauthorized starting 87 87a 85 30 86 IN4003 Diode H2 15 Orange wire from control module Start On Purple wire X Cut Yello wire White wire Acc Off Starter H1 1 VIOLET wire Starter output form Heavy Gauge wire harness Re...

Page 11: ...hicle has the General Motor VATS system installed you will need to by pass the system while the vehicle is operating under the control of the Remote Start Unit To do this 1 Measure the resistance of the resistor pellet on the ignition key then select a resistor within 5 of the key s value 2 Locate the pair of VATS wires in the vehicle usually a pair of thin gauge wires running from the ignition sw...

Page 12: ...icates 12 volts until the light goes out you have isolated the connect wire and the wire s polarity is negative ground while the bulb is on 6 If the meter reads zero volts until the light goes out and then reads 12 volts you have isolated the connect wire and the wire s polarity is positive Connect this wire to the wire in the vehicle that sends the signal to turn on the WAIT TO START bulb in the ...

Page 13: ...ter will receive 12 volts Cut this wire and make connections Be sure to program door lock timer to 3 5 seconds See Alarn Feature B 3 Programming 12V Master Door Lock Switch X X Splice Splice Cut the Existing Lock Wire To Door Lock Motor To Slave Door Lock switches Cut the Existing Unlock Wire 3 Pin Plug To Alarm 5 WIRE ALTERNATING DOOR LOCK 30 86 87a 85 87 30 86 87a 85 87 Red 12V Green Wire Blue W...

Page 14: ...g mode 3 Press and hold any button of the transmitter until the siren responds with a confirming chirp indicating the signal has been stored into memory 4 If you have additional transmitters up to 4 that need to be programmed repeat step 3 for each transmitter Exit Turn Ignition to OFF position or leave it for 15 seconds 3 long chirps 3 parking light flashes will confirm exit FEATURES PROGRAMMING ...

Page 15: ...hirp With Dome light turns on after ignition off Some vehicles turn on the dome light when ignition key is turned off After remote start with alarm on a false alarm may occur when the run time elapses and the dome light comes on To prevent this from happing program Alarm Feature A 8 to With Dome light turns on after ignition off 45 second door by pass ALARM FEATURE B PROGRAMMING 1 Turn the Ignitio...

Page 16: ...e and the shock sensor will be by passed upon engine running Five chirps Press and buttons at the same time to control Engine run time for three minutes and the shock sensor will be by pass upon engine running Six chirps Press and buttons at the same time to control Engine run time for five minutes and the shock sensor will be by passed upon engine running 7 Horn chirp Duration Standard Horn chirp...

Page 17: ... reset with ignition on Black Green Wire Channel 4 Output Timer programming set to any interval between 1 second and 2 minutes 6 Black Red Wire Channel 5 Output Pulse output White Red Channel 5 Output Latched output White Red Channel 5 Output Latched output and reset with ignition on White Red Channel 5 Output Timer programming set to any interval between 1 second and 2 minutes 7 Black Violet Wire...

Page 18: ...itch to OFF position If the new password code was accepted the unit would report back the newly entered code by flashing the LED first indicating the first digit code has been memorized pause and then the second digit code The unit will report the new code three times with a one second s pause between each code Note If 15 seconds of inactivity expire or if the ignition switch is turned ON for more...

Page 19: ...e 30 minutes run time 10 minutes run time 5 minutes run time 5 Door lock After start RUN Door un lock before start Lock after start Door lock before start and Door lock after shut down Without this feature 6 Temperature Control Starting OFF Temperature Co ntrol Starting ON 0 ºF 18 ºC Temperature Cont rol Starting ON 15 ºF 9 ºC 7 Press button Activate Remote Start Press button Activate Remote Start...

Page 20: ...0 RPM DBI ONLY No RPM Learning or 50RPM 9 Automatic Transmission Manual Transmission Exit Press the button on the transmitter 3 long chirps 3 parking light flashes will confirm exit RPM LEARNING TACHOMETER CHECKING TYPE 1 Turn the Ignition switch ON OFF 3 TIMES and stay in OFF position 2 Push the Valet switch 7 times and hold it on the 7 th push until a long chirp is hearing then release the valet...

Page 21: ... you can adjust and test Start Timer as below START CRANK TIME PROGRAMMING TEST and ADJUST 1 Press button once on the transmitter to start the vehicle 2 If everything goes well Wait for 15 seconds a If the engine still running I Press button once on the transmitter to stop engine running You have been completed this programming successfully II Press button on the transmitter to exit the program mo...

Page 22: ...ensors Enter 1 Turn the Ignition switch ON OFF 3 TIMES and stay in OFF position 2 Push the Valet switch 7 times holding in on the 7 th until one long chirp is heard then release the valet switch You are now in the Start feature E programming mode a Test the Zone 2 Instant Ground Trigger Zone 3 Door Trigger Press and release the transmitter and buttons at the same time once 1 LED flash 1 siren horn...

Page 23: ...emote start feature programming has not been programmed to start the vehicle The remote start must be programmed how to start the vehicle SHUTDOWN DIAGNOSTICS The unit has the ability to report the cause of the last shutdown of the remote start system Enter 1 Turn the Ignition switch to ON position 2 Press the button on the transmitter 3 The LED will now report the last system shutdown by flashing...

Page 24: ...is in gear but offers no consideration for electrical operation Because of this potential problem this installation requires the additional connection of a safety wire from the remote start device to the vehicle PARK NEUTRAL ECM input or the vehicle key in sensor This connection will prevent remote start operation if the key is left in the ignition switch regardless of the gear selector position P...

Page 25: ...Remote Start Unit F Connect terminal 86 of the relay to a fused 12 volt constant battery source G Connect terminal 87 of the relay to the Chime Module side of the previously cut wire in step D H Connect terminal 85 of the relay to the Drivers Door side of the pin switch wire previously cut in step B Note A second 4003 series diode may be required to maintain the integrity of the hood open shut dow...

Page 26: ...onsidered void if the equipment has been misused neglected improperly serviced or installed altered dropped or damaged by water contrary to the Encore OPERATIONS MANUAL Or if used with accessories not approved by Encore which may have contributed to the defect See note below regarding product installation 4 The purchaser s remedies under this WARRANTY shall be limited to the repair or replacement ...

Page 27: ... as an ingredient in solid fuel for rockets and missiles In addition perchlorate based chemicals are also used in the construction of highway safety flares fireworks pyrotechnics explosives common batteries and automobile restraint systems Perchlorate contamination has been reported in at least 20 states Perchlorate greatly impacts human health by interfering with iodide uptake into the thyroid gl...

Reviews: