3
5.
Place the funnel in the open valve and press down gently to secure it in place.
6.
Fill the bag with 3.7-4.0 gallons of potable water (14.0-15.1 L).
Note: Filling the cartridge with the correct amount of water is critical to the
system meeting the ANSI Z358.1 Standard.
Figure 5: Funnel installed for filling.
7.
Gently lift the bag by the fill port to allow any air bubbles to escape.
8.
Replace the cap in the port; it will be secure when the cap clicks into place.
9.
Write the date filled on the Aquarion label provided and place it on the bag.
Note: If at any time the system is activated, the entire cartridge must be
replaced as this is a onetime use cartridge.