ENC-900 Operating Manual: Chapter 4 Configuration
23
Refer to Appendix A for a
summary of the S-Registers.
S Registers 2 cannot be
stored to non-volatile
memory.
4.3 S Registers
The S Registers described in this section affect the operating characteristics
of the modem.
S Register 0 - Auto Answer
If this register is set to zero, the modem will power up in command mode. If
this register is set to one, the modem will power up in data mode.
S Register 2 - Escape Code
This register contains the ASCII value of the escape character.
The default value (decimal 43) is equivalent to the ASCII character ‘+’.
Values greater than 127 disable the escape feature and prevent you from
returning to the Command Mode. This register cannot be stored to non-
volatile memory. If the modem is reset, or powered down, the default value
is restored.
Default is ‘+’ (decimal 43).